SCS120PW48 TDK Corporation, SCS120PW48 Datasheet - Page 74

POWER SUP 48V 2.5A 120W OUTPUT

SCS120PW48

Manufacturer Part Number
SCS120PW48
Description
POWER SUP 48V 2.5A 120W OUTPUT
Manufacturer
TDK Corporation
Series
SCS120PWr
Datasheets

Specifications of SCS120PW48

Voltage - Output
48V
Number Of Outputs
1
Power (watts)
120W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
48 VDC @ 2.5A
Size / Dimension
5" L x 3" W x 1.27" H (127mm x 76.2mm x 32.3mm)
Power (watts) - Rated
120W
Operating Temperature
0°C ~ 40°C
Efficiency
85%
Approvals
CE, CSA, EN, UL
Line Regulation
±3%
Load Regulation
±3%
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
48V
Output Current
2.5A
Power Rating
120W
Input Voltage
90VAC To 264VAC
Supply Voltage Typ
115VAC / 230VAC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
285-1969
Notes:
Features and Benefits
Feature
Specifications
ITEMS
Input Voltage range
Inrush Current
Power Factor Harmonics
Total Regulation
Ripple & Noise
Efficiency
Minimum Load
Overcurrent Protection
Overvoltage Protection
Overtemperature Protection
Hold Up Time (Typ)
Leakage Current (max)
Remote Sense
DC Good
Remote On//Off
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Isolation
Vibration (non operating)
Shock
Safety Agency Certifications
Immunity
Conducted Emissions and Flicker
Radiated Emissions
Weight (Typ)
Size (pcb version)
Warranty
(1) -20°C cold start
(2) Including underside component leads
High Efficiency
Low Profile
No Minimum Loads
MODEL
(2)
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
mV
ms
µA
in
yr
A
A
V
g
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Forced air 2m/s from input to output unless internal, temperature controlled, fan is specified
UL, CSA, EN and IEC60950-1; EN and IEC61010-1; UL, EN and IEC60601-1; CE for LVD
123µA 120VAC, 60Hz; 257µA 240VAC 60Hz, <300µA 264VAC, 63Hz (Type Test result)
Conforms to MIL-STD-810E/F, Method 514.4, Pro I, Cat 1,9; EN60068-2-27, -2-47,
Conforms to MIL-STD-810E, Method 516.5, Pro I, IV, VI; EN60068-2-6; IEC68-2-6
Input to Ground 2.25kVDC, Input to Output 4.3kVDC, Output to Ground 200VDC
NV300 Series
TTL logic level high (or open) will inhibit all outputs (except standby)
90 - 264VAC (45-63Hz, 440Hz with reduced PFC)120 - 350VDC
0 to +70°C. Derate linearily to 50% load from 50°C to 70°C(1)
EN55011, EN55022 Class B (per CISPR.11/22), EN61000-3-3
3.75 x 7.25 x 1.34 (4.72 x 7.25 x 1.34 for N option version)
On Outputs CH1 & CH2, 0.5V Maximum compensation
EN50082-2: EN61000-4-2, -3, -4, -5, -6, -8, -11, -14
Logic low signal indicates CH1 is within regulation
EN55011, EN55022 Class B (per CISPR.11/22)
EN61000-3-2 Class A Compliant, 0.97 typical
<15A at 25C and 264VAC input, Cold Start
3.75" x 7.25" 300W Power Supplies
Benefit
1% or 50mV (whichever is the greater)
Industrial Computing and Routers
Test & Measurement
IEC68-2-27, -2-47, JIS C0041-1987
Up to 90%, configuration dependant
Yes, see application notes for details
Key Market Segments & Applications
(Contact factory for agency status)
Less heat dissipated in system
Fits in 1U enclosures
Ease of Use
CH1-3: 1.5%, CH4: 2.5%
Medical Safety Certifications
Universal Input (90 - 264VAC)
Up to 5 Outputs (including standby)
No Minimum Loads
>16ms at 90VAC Input
(300W Output Power)
-40 to +85°C
5 - 95% RH
Three Years
NV300
None
470
Yes
Yes
Broadcast
Medical
73