SCS120PW48 TDK Corporation, SCS120PW48 Datasheet - Page 138
SCS120PW48
Manufacturer Part Number
SCS120PW48
Description
POWER SUP 48V 2.5A 120W OUTPUT
Manufacturer
TDK Corporation
Series
SCS120PWr
Datasheets
1.SCS120PW48.pdf
(2 pages)
2.SCS120PW48.pdf
(2 pages)
3.SCS120PW48.pdf
(1 pages)
4.SCS120PW48.pdf
(169 pages)
Specifications of SCS120PW48
Voltage - Output
48V
Number Of Outputs
1
Power (watts)
120W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
48 VDC @ 2.5A
Size / Dimension
5" L x 3" W x 1.27" H (127mm x 76.2mm x 32.3mm)
Power (watts) - Rated
120W
Operating Temperature
0°C ~ 40°C
Efficiency
85%
Approvals
CE, CSA, EN, UL
Line Regulation
±3%
Load Regulation
±3%
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
48V
Output Current
2.5A
Power Rating
120W
Input Voltage
90VAC To 264VAC
Supply Voltage Typ
115VAC / 230VAC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
285-1969
F e a t u r e s a n d B e n e f i t s
S p e c i f i c a t i o n s
Feature
ITEMS
Input range
Output Voltage Adj. Range
Line Regulation
Load Regulation
Ripple and Noise
Series Operation
Over Voltage Protection
Overload Protection
Remote On/Off
Remote Sensing
Parallel operation
Inverter Good signal
Auxiliary Bias Supply
Thermal Protection
Cooling
Operating Temperature Range
Storage Temperature
Temperature Coefficient
Isolation
Isolation Resistance
Safety Agency Approval
Warranty
Note: See Installation Manual for full details, test methods of parameters and application notes
(1) 24V input models input to output: 2kVAC; input to baseplate: 2kVAC
Low component count
Wide output adjustment
Signals to support N+1 redundancy
Variety of input voltages
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
pk-pk
VDC
VDC
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1.6~2.4
Using current share pin (PC). Will share within 5%, see app. notes for connection details
0.8% or 40mV (whichever is greater) from no load to full load with constant input line
Conduction or forced air. See application notes for cooling and heatsink selection
2V
24V nom: 18-36, 48V nom: 36-76V, 110V nom: 82-185V, 280V nom: 200-400V
Baseplate temperature -20°C to +85°C. -40°C start up possible - consult factory
Possible - Refer to installation manual
0.4% or 20mV (whichever is greater) over entire input range with constant load
150 - 180%
8V 10mA auxiliary voltage to supply power to interface circuits (AUX pin)
2.64~3.96
Input to output: 3000VAC, Input to Baseplate: 2500VAC(1)
100mV
Output to Baseplate -100MOhm at 500VDC and 70%RH
3.3V
UL60950-1, CSA60950-1, EN60950-1 and CE Mark.
Full function, 50 to 300W DC-DC converters
PH-F Series
Approximately 105 - 140%, automatic recovery
Signal available for status of inverter
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
Telecom
Custom Power Supplies
N+1 redundant systems
Scalable systems
Point of Load
2~6
High Density
Wide Range Input
Wide output adjustment capability
Remote On/Off
Fixed Switching Frequency
International Safety Approvals
Parallel Operation
Internal sensing, self resetting
5V
Benefit
Low = ON, Open = OFF
High reliability demonstrated 5 million hours MTBF
Avoids the need for custom modules
Ease of use in redundant configurations
Systems can operate from different input voltages
-40°C to +85°C
4.8~14.4
0.02%/°C
Two years
12V
Yes
150mV
125 - 145%
6~18
15V
9.6~28.8
240mV
24V
11.2~33.6
280mV
28V
137