POWER SUP 48V 2.5A 120W OUTPUT

SCS120PW48

Manufacturer Part Number
SCS120PW48
Description
POWER SUP 48V 2.5A 120W OUTPUT
Manufacturer
TDK Corporation
Series
SCS120PWr
Datasheets

Specifications of SCS120PW48

Voltage - Output
48V
Number Of Outputs
1
Power (watts)
120W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
48 VDC @ 2.5A
Size / Dimension
5" L x 3" W x 1.27" H (127mm x 76.2mm x 32.3mm)
Power (watts) - Rated
120W
Operating Temperature
0°C ~ 40°C
Efficiency
85%
Approvals
CE, CSA, EN, UL
Line Regulation
±3%
Load Regulation
±3%
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
48V
Output Current
2.5A
Power Rating
120W
Input Voltage
90VAC To 264VAC
Supply Voltage Typ
115VAC / 230VAC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
285-1969
Features and Benefits
Specifications
Feature
ITEMS
Input Voltage Range
Inrush Current Limiting
Input Current (115 / 230VAC)
Recommended External Fuse
Temperature Coefficient
Ripple and Noise (pk-pk)
Overcurrent Protection
Overvoltage Protection
Hold-up Time (typical)
Enclosure Leakage (240VAC 63Hz)
Operating Temperature
Storage Temperature
Humidity
Cooling
Withstand Voltage
Immunity
Safety Agency Certification
Conducted EMI
Switching Frequency
Weight
Size (LxWxH)
Mounting & Case
MTBF
Warranty
(1)
Small size
Wide input range
High efficiency
KM15 derates linearly to 40% load
(264VAC 63Hz)
MODELS
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
%RH
VAC
kHz
mA
mA
mV
hrs
ms
yrs
in
A
%
g
-
-
-
-
-
-
-
-
-
-
-
-25°C to 70°C, derate linearly to 50%(1) load from 50°C to 70°C. Max case temperature 95°C
15-40W Medical AC-DC PCB-Mount Power Supplies
KMS15
EN55011, EN55022 Class B
2.52 x 1.79 x 0.92"
Convection, over temperature protected ~100°C case temperature)
2A slow blow type
220 / 118mA
PC board mountable. Plastic resin fiberglass case (UL 94V-0)
0.055 max
0.06 max
KMD15
20ms
120
10 / 20A, cold start, 25°C ambient (115 / 230VAC)
UL60601-1, IEC60601-1, CE Mark, EN60950-1
200,000 to 400,000 hours, model dependant
> 105%, hiccup mode, automatic recovery
90-264VAC 47-440Hz or 100-375VDC
Benefit
Minimizes pcb space
Global use with no manual intervention
Lower heat dissipated in system
50mV or 1%, whichever is greater
20% to 95% RH (non-condensing)
Small size and lightweight
PC Board Mountable
Wide Range Input
Medical Safety Certifications (4kVAC Input - Output)
Class II (No ground needed)
KM Series
Yes, Zener diode clamp
Input to output: 4kVAC
KMT15
-40°C to 100°C
EN60601-1-2
±0.01%/°C
132kHz
2 years
KMS40
EN55011, EN55022 Class A
3.15A slow blow type
3.5 x 2.5 x 1.06"
860 / 460mA
0.085 max
0.08 max
KMD40
18ms
280
KMT40
53