POWER SUP 48V 2.5A 120W OUTPUT

SCS120PW48

Manufacturer Part Number
SCS120PW48
Description
POWER SUP 48V 2.5A 120W OUTPUT
Manufacturer
TDK Corporation
Series
SCS120PWr
Datasheets

Specifications of SCS120PW48

Voltage - Output
48V
Number Of Outputs
1
Power (watts)
120W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
48 VDC @ 2.5A
Size / Dimension
5" L x 3" W x 1.27" H (127mm x 76.2mm x 32.3mm)
Power (watts) - Rated
120W
Operating Temperature
0°C ~ 40°C
Efficiency
85%
Approvals
CE, CSA, EN, UL
Line Regulation
±3%
Load Regulation
±3%
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
48V
Output Current
2.5A
Power Rating
120W
Input Voltage
90VAC To 264VAC
Supply Voltage Typ
115VAC / 230VAC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
285-1969
Note:
F e a t u r e s a n d B e n e f i t s
S p e c i f i c a t i o n s
Feature
ITEMS
Input Voltage Range
Number of inputs
Maximum Input Current
Maximum Output Current
Overcurrent protection
Voltage Drop
Maximum Reverse Voltage
LED Indicators
Input Voltage Alarm
Relay contact rating (max)
Cooling
Operating Temperature
Storage Temperature
Humidity
Withstand Voltage
Isolation Resistance
Vibration
Shock
Safety Agency Approval
Size
Weight
Warranty
See Installation Manual for full details, test methods of parameters and application notes
Internal ORing Diodes
Can connect two units in parallel
Output voltage monitoring (via relays)
DIN Rail Mounting
MODELS
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
mm/in
VDC
VDC
VDC
yrs
A
A
g
-
-
-
-
-
-
-
-
-
-
-
-
-
UL60950-1, CSA60950-1, EN60950-1, UL508, CSA22.2 No.14, EN60529 IP20, EN50178 Cat 1
Power Supply Parallel or Redundancy Module
DLP-PU Series
Relay off when input is <19.2V (±1%) or > 30V (±5%). NO and NC contacts
Relay Contacts to Chassis; >10M Ohms at 25°C, 70%RH and 500VDC
Non operating, mounted on DIN Rail,10-55Hz (sweep for 1 min),
Operating: 30 - 90%RH, Storage: 10 - 95%RH (non condensing)
28VDC, 1A or 120VAC, 0.5A (5mA minimum recommended)
Input or Output - Chassis, Input or Output - Relay Contacts,
Input or Output - Chassis, Input or Output - Relay Contacts,
-10 to +70°C, derate linearly to 60% from 60 to 70°C
Two green LEDs indicating each input is "good"
Relay Contacts to Chassis; 500VAC for 1 min.
9.8m/s
50 x 97 x 110mm, 1.97x 3.81 x 4.33"
Benefit
OR-ing Diodes Included
Alarm Signals
LED Indicators
DIN Rail Mounting
2
Allows redundant operating
Enables system scalability
Remote alarm notification
Easier system integration
constant X, Y, Z each for 1 hour
20A per input
-30 to +90°C
21 - 28VDC
Three Years
Convection
DLP-PU/E
196m/s
35VDC
None
470g
0.5V
20A
Two
2
23