KP-F1 Panduit Corp, KP-F1 Datasheet - Page 414

KIT FERRULE NONINS AWG22-14

KP-F1

Manufacturer Part Number
KP-F1
Description
KIT FERRULE NONINS AWG22-14
Manufacturer
Panduit Corp
Series
Pan-Term®r
Type
Ferrule kitr
Datasheet

Specifications of KP-F1

Kit Type
Ferrule - Wire End
Values
370 pcs - Assorted Non-Insulated 22 ~ 14 AWG Ferrules
Kit Contents
500 Pieces Of F75-6, 400 Pieces Of F76-6 & F77-6, 300 Pieces Of F78-7, 200 Pieces Of F80-7
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Management
Identification
Accessories
Connectors
Connectors
& Write-On
Protection
Grounding
Pre-Printed
Cable Ties
Terminals
Permanent
Solutions
Overview
Steel Ties
Lockout/
& Safety
Stainless
Raceway
Abrasion
Labeling
Systems
C2.112
Markers
Tagout
System
Surface
Wiring
Power
Labels
Index
Cable
Cable
Duct
E5.
B1.
B2.
B3.
C1.
C2.
C3.
C4.
D1.
D2.
D3.
E1.
E2.
E3.
E4.
A.
F.
AWG dimensions represent typical outer cable diameter in inches.
Cable Fill Capacities for Pan-Pole
The maximum amounts may vary according to the cable installation methods, straightness of cables, etc.
SPEC = 40% cable fill – The recommended design in cable
capacity, leaves room for future moves, adds, and changes.
1A.
1B.
2A.
2B.
3.
4.
Power and communication:
snap-on faceplates (power).
Communication.
Power and communication:
Screw-on faceplates (power).
Communication.
Communication only
Snap-on faceplate.
Communication only:
Screw-on faceplates.
CR-SR-PanPole-WireFill1
Raceway Type and
Configuration
Cable fill #1: Power pole with data
snap-on communication faceplate.
Cable fill #3: Communication pole
terminals using vertical sloped
using vertical sloped snap-on
A = .47 in.
2A
communication faceplate.
Area
(In.²)
0.47
2.75
0.43
2.15
3.47
2.83
Fill
A = 3.47 in.
2
3
0.111
AWG
MAX
A = 2.75 in.
14
(UL Temp Rise Test)
Electrical Cables
2
THHN/T90
2B
0.130
AWG
FILL
MAX
12
11
11
ELECTRICAL SOLUTIONS
2
AWG
0.164
MAX
10
Power and Communication Poles
Data Grade Cables
24 AWG/UTP CM
SPEC
(40%)
22
17
28
23
Cat. 6 (4-pr.)
DIA .= 0.250
MAX for Data = 60% cable fill – The maximum cable quantity
based on cable interweaving and packing factors.
MAX for Power cable fill – The maximum of electrical cables
based on UL temperature rise test.
FILL
Cable fill #2: Power pole with data
Cable fill #4: communication pole
terminals using sloped screw-on
(60%)
MAX
A = .43 in.
2A
communication faceplate.
33
26
42
34
communication faceplate.
using sloped screw-on
A = 2.83 in.
Data Grade Cables
Augmented Cat. 6
24 AWG/UTP CM
SPEC
(40%)
2
12
10
16
13
DIA. = 0.354
4
A = 2.15 in.
FILL
2
(60%)
MAX
2B
19
15
24
19
2
SPEC
(40%)
Audio/Video
DIA. = 0.275
32
18
14
23
19
2
RG6
FILL
(60%)
MAX
27
21
35
28
4
4
SPEC
(40%)
DIA. = 0.175
Fiber Optic
45
35
57
47
7
7
2 Strand
Cable
FILL
(60%)
MAX
11
68
10
53
86
70