KP-F1 Panduit Corp, KP-F1 Datasheet - Page 247

KIT FERRULE NONINS AWG22-14

KP-F1

Manufacturer Part Number
KP-F1
Description
KIT FERRULE NONINS AWG22-14
Manufacturer
Panduit Corp
Series
Pan-Term®r
Type
Ferrule kitr
Datasheet

Specifications of KP-F1

Kit Type
Ferrule - Wire End
Values
370 pcs - Assorted Non-Insulated 22 ~ 14 AWG Ferrules
Kit Contents
500 Pieces Of F75-6, 400 Pieces Of F76-6 & F77-6, 300 Pieces Of F78-7, 200 Pieces Of F80-7
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Panduct
• Metal noise barrier reduces EMI noise coupling between noise
• Installs directly to metal panel surface or within 2, 3, or 4 inch
• Perforated and pre-scored sections speed installation by allowing
Relative noise reduction in dB over frequency range of the PanelMax
Performance Characteristics
emitting and sensitive cabling within a control panel; provides
up to 20dB reduction in noise which is equivalent to 6 inches
of air spacing
height Panduit wiring duct (when shield is installed with supplied
bonding clips)
sections of the shield to be snapped off at pre-scored locations
to easily cut to length with minimal deburring required
-10
-20
-30
-40
-50
0
0
PanelMax
reduction across common industrial noise frequencies at 30mm
wire separation.
Noise Coupling vs. Frequency
®
2.0
PanelMax
Noise Shield delivers approximately 20dB of noise
Noise Frequency (MHz)
4.0
6.0
Noise Shield
8.0
Part Number
SD2EMI
SD3EMI
SD4EMI
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
10.0
ELECTRICAL SOLUTIONS
No Shield
PanelMax
Noise
Shield
EMI Noise Shield kit for 2" height Panduit Wiring Duct; (2) three foot
sections, bonding clips, and anti-oxidizing paste.
EMI Noise Shield kit for 3" height Panduit Wiring Duct; (2) three foot
sections, bonding clips, and anti-oxidizing paste.
EMI Noise Shield kit for 4" height Panduit Wiring Duct; (2) three foot
sections, bonding clips, and anti-oxidizing paste.
• Vertical wall slots allow wires to cross the
• Horizontal cable tie slots allow cable bundles to be held in
• Zinc plated steel surface in contact areas with sub-panel
• Black powder coated vertical surface for smooth edges
• Meets UL 508/508A requirements as a barrier between conductors
barrier at 90° when necessary, providing
greater design flexibility
place using cable ties so cabling is kept near barrier for greater
reliability and optimal aesthetics
and bonding clip ensures continuity and is corrosion resistant
Noise Shield is shown below.
Part Description
Pkg.
Std.
Qty.
1
1
1
C1.7
Management
Identification
Accessories
Connectors
Connectors
Grounding
Pre-Printed
& Write-On
Protection
Permanent
Solutions
Cable Ties
Terminals
Lockout/
Overview
Steel Ties
& Safety
Stainless
Raceway
Abrasion
Labeling
Systems
Surface
Markers
Tagout
System
Wiring
Labels
Power
Cable
Cable
Index
Duct
E5.
B1.
B2.
B3.
D1.
D2.
D3.
C1.
C2.
C3.
C4.
E1.
E2.
E3.
E4.
A.
F.