ADT7463ARQZ ON Semiconductor, ADT7463ARQZ Datasheet - Page 9

IC REMOTE THERMAL CTRLR 24-QSOP

ADT7463ARQZ

Manufacturer Part Number
ADT7463ARQZ
Description
IC REMOTE THERMAL CTRLR 24-QSOP
Manufacturer
ON Semiconductor
Series
dBCool®r
Datasheet

Specifications of ADT7463ARQZ

Function
Fan Control, Temp Monitor
Topology
ADC, Comparator, Fan Speed Counter, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 120°C, External Sensor
Output Type
SMBus™
Output Alarm
No
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 120°C
Mounting Type
Surface Mount
Package / Case
24-QSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADT7463ARQZ
Manufacturer:
AD
Quantity:
10
Part Number:
ADT7463ARQZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
ADT7463ARQZ
Quantity:
43
Company:
Part Number:
ADT7463ARQZ
Quantity:
43
Part Number:
ADT7463ARQZ-REEL
Manufacturer:
ONSEMI
Quantity:
2 785
Part Number:
ADT7463ARQZ-REEL
Manufacturer:
ADI/PBF
Quantity:
56
Part Number:
ADT7463ARQZ-REEL
Manufacturer:
ON/安森美
Quantity:
20 000
SERIAL BUS INTERFACE
Control of the ADT7463 is carried out using the serial system
management bus (SMBus). The ADT7463 is connected to this
bus as a slave device, under the control of a master controller.
The ADT7463 has a 7-bit serial bus address. When the device
is powered up with Pin 13 (PWM3/ADDRESS ENABLE) high,
the ADT7463 has a default SMBus address of 0101110 or
0x2E. The read/write bit must be added to get the 8-bit address. If
more than one ADT7463 is used in a system, then each ADT7463
should be placed in address select mode by strapping Pin 13 low on
power-up. The logic state of Pin 14 then determines the device’s
SMBus address. The logic of these pins is sampled upon power-up.
The device address is sampled and latched on the first valid
SMBus transaction, more precisely on the low-to-high transition
at the beginning of the 8th SCL pulse, when the serial bus address
byte matches the selected slave address. The selected slave address
is chosen using the address enable/address select pins. Any
attempted changes in the address will have no effect after this.
Pin 13 State
0
0
1
REV. C
Figure 4. SMBus Address = 0x2C (Pin 14 = 0)
Figure 3. Default SMBus Address = 0x2E
Table I. Address Select Mode
PWM3/ADDR_EN
PWM3/ADDR_EN
Pin 14 State
Low (10 kΩ to GND)
High (10 kΩ Pull-Up)
Don’t Care
ADT7463
ADT7463
ADDR_SEL
ADDR_SEL
14
13
14
13
ADDRESS = 0x2E
10k�
ADDRESS = 0x2C
V
CC
10k�
Address
0101100 (0x2C)
0101101 (0x2D)
0101110 (0x2E)
(Default)
Rev. 4 | Page 9 of 52 | www.onsemi.com
–9–
The ability to make hardwired changes to the SMBus slave
address allows the user to avoid conflicts with other devices sharing
the same serial bus, for example, if more than one ADT7463 is
used in a system.
The serial bus protocol operates as follows:
1. The master initiates data transfer by establishing a START
condition, defined as a high-to-low transition on the serial
data line SDA while the serial clock line SCL remains high.
This indicates that an address/data stream will follow. All
slave peripherals connected to the serial bus respond to the
START condition and shift in the next eight bits, consisting
of a 7-bit address (MSB first) plus a R/W bit, which deter-
mines the direction of the data transfer, i.e., whether data
will be written to or read from the slave device.
The peripheral whose address corresponds to the transmitted
address responds by pulling the data line low during the low
period before the ninth clock pulse, known as the Acknowl-
edge Bit. All other devices on the bus now remain idle while
the selected device waits for data to be read from or written
to it. If the R/W bit is a 0, then the master writes to the
slave device. If the R/W bit is a 1, the master reads from
the slave device.
Figure 6. Unpredictable SMBus Address if Pin 13
Is Unconnected
CARE SHOULD BE TAKEN TO ENSURE THAT PIN 13
(PWM3/ADDR_EN) IS EITHER TIED HIGH OR LOW. LEAVING PIN 13
FLOATING COULD CAUSE THE ADT7463 TO POWER UP WITH AN
UNEXPECTED ADDRESS.
NOTE THAT IF THE ADT7463 IS PLACED INTO ADDRESS SELECT
MODE, PINS 13 AND 14 CANNOT BE USED AS THE ALTERNATE
FUNCTIONS (PWM3, TACH4/THERM) ONLY IF THE CORRECT
CIRCUIT IS MUXED IN AT THE CORRECT TIME.
Figure 5. SMBus Address = 0x2D (Pin 14 = 1)
PWM3/ADDR_EN
PWM3/ADDR_EN
ADT7463
ADT7463
ADDR_SEL
ADDR_SEL
14
13
14
13
V
V
CC
DO NOT LEAVE ADDR_EN
UNCONNECTED! CAN
CAUSE UNPREDICTABLE
ADDRESSES.
NC
CC
10k�
10k�
ADDRESS = 0x2D
ADT7463