ISL62392HRTZ Intersil, ISL62392HRTZ Datasheet - Page 17

IC PWR SUPPLY CONTROLLER 28TQFN

ISL62392HRTZ

Manufacturer Part Number
ISL62392HRTZ
Description
IC PWR SUPPLY CONTROLLER 28TQFN
Manufacturer
Intersil
Datasheet

Specifications of ISL62392HRTZ

Applications
Power Supply Controller
Voltage - Supply
5.5 V ~ 25 V
Current - Supply
150µA
Operating Temperature
-10°C ~ 100°C
Mounting Type
Surface Mount
Package / Case
28-TQFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Input
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ISL62392HRTZ
Manufacturer:
Intersil
Quantity:
35
Part Number:
ISL62392HRTZ
Manufacturer:
INTESIL
Quantity:
20 000
Company:
Part Number:
ISL62392HRTZ
Quantity:
248
Part Number:
ISL62392HRTZ-T
Manufacturer:
INTERSIL
Quantity:
20 000
The inductance of the capacitor can cause a brief voltage dip
if the load transient has an extremely high slew rate. Low
inductance capacitors should be considered in this scenario.
A capacitor dissipates heat as a function of RMS current and
frequency. Be sure that I
of paralleled capacitors so that they operate below the
maximum rated RMS current at f
the rated value of a capacitor can fade as much as 50% as
the DC voltage across it increases.
Selection of the Input Capacitor
The important parameters for the bulk input capacitance are
the voltage rating and the RMS current rating. For reliable
operation, select bulk capacitors with voltage and current
ratings above the maximum input voltage and capable of
supplying the RMS current required by the switching circuit.
Their voltage rating should be at least 1.25x greater than the
maximum input voltage, while a voltage rating of 1.5x is a
preferred rating. Figure 28 is a graph of the input RMS ripple
current (normalized relative to output load current) as a
function of duty cycle and is adjusted for a converter efficiency
of 80%. The ripple current calculation is written as
Equation 21:
Where:
In addition to the bulk capacitance, some low ESL ceramic
capacitance is recommended to decouple between the drain
of the high-side MOSFET and the source of the low-side
MOSFET.
I
D
IN_RMS NORMALIZED
- I
- x is a multiplier (0 to 1) corresponding to the inductor
- D is the duty cycle that is adjusted to take into account
=
peak-to-peak ripple amplitude expressed as a
percentage of I
the efficiency of the converter which is written as
Equation 22.
MAX
------------------------- -
V
IN
,
V
O
is the maximum continuous I
EFF
MAX
=
P-P
(0% to 100%)
(
is shared by a sufficient quantity
D D
17
SW
2
)
ISL62391, ISL62392, ISL62391C, ISL62392C
+
. Take into account that
D
LOAD
x
----- -
12
2
of the converter
(EQ. 21)
(EQ. 22)
MOSFET Selection and Considerations
Typically, a MOSFET cannot tolerate even brief excursions
beyond their maximum drain to source voltage rating. The
MOSFETs used in the power stage of the converter should
have a maximum V
upper voltage tolerance of the input power source and the
voltage spike that occurs when the MOSFET switches off.
There are several power MOSFETs readily available that are
optimized for DC/DC converter applications. The preferred
high-side MOSFET emphasizes low gate charge so that the
device spends the least amount of time dissipating power in
the linear region. Unlike the low-side MOSFET, which has
the drain-source voltage clamped by its body diode during
turn off, the high-side MOSFET turns off with a V
approximately V
preferred low-side MOSFET emphasizes low r
fully saturated to minimize conduction loss. It should be
noted that this is an optimal configuration of MOSFET
selection for low duty cycle applications (D < 50%). For
higher output, low input voltage solutions, a more balanced
MOSFET selection for high- and low-side devices may be
warranted.
For the low-side (LS) MOSFET, the power loss can be
assumed to be conductive only and is written as Equation 23:
For the high-side (HS) MOSFET, the conduction loss is
written as Equation 24:
For the high-side MOSFET, the switching loss is written as
Equation 25:
P
P
P
CON_LS
CON_HS
SW_HS
0.60
0.55
0.50
0.45
0.40
0.35
0.30
0.25
0.20
0.15
0.10
0.05
FIGURE 28. NORMALIZED RMS INPUT CURRENT
0
0
=
=
I
V
---------------------------------------------------------------- -
LOAD
0.1
I
IN
LOAD
I
IN
VALLEY
2
0.2
- V
2
r ⋅
DS
DS ON
r
OUT
DS ON
2
0.3
rating that exceeds the sum of the
(
(
t
, plus the spike across it. The
ON
)_LS
x = 1
x = 0.75
x = 0.50
x = 0.25
x = 0
0.4
DUTY CYCLE
)_HS
f
SW
0.5
(
1 D
D
+
V
------------------------------------------------------------ -
0.6
IN
)
I
PEAK
0.7
2
0.8
DS(ON)
t
OFF
DS
0.9
(EQ. 25)
April 7, 2011
of
(EQ. 23)
(EQ. 24)
f
SW
FN6666.5
when
1.0

Related parts for ISL62392HRTZ