IS42S32200C1-6TL ISSI, Integrated Silicon Solution Inc, IS42S32200C1-6TL Datasheet - Page 29

no-image

IS42S32200C1-6TL

Manufacturer Part Number
IS42S32200C1-6TL
Description
IC SDRAM 64MBIT 166MHZ 86TSOP
Manufacturer
ISSI, Integrated Silicon Solution Inc
Datasheet

Specifications of IS42S32200C1-6TL

Format - Memory
RAM
Memory Type
SDRAM
Memory Size
64M (2Mx32)
Speed
166MHz
Interface
Parallel
Voltage - Supply
3.15 V ~ 3.45 V
Operating Temperature
0°C ~ 70°C
Package / Case
86-TSOPII
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IS42S32200C1-6TL
Manufacturer:
ISSI
Quantity:
5 520
Part Number:
IS42S32200C1-6TL
Manufacturer:
ISSI
Quantity:
54
Part Number:
IS42S32200C1-6TL
Manufacturer:
ISSI
Quantity:
1 000
Part Number:
IS42S32200C1-6TL
Manufacturer:
ISSI
Quantity:
20 000
Part Number:
IS42S32200C1-6TLI
Manufacturer:
SIEMENS
Quantity:
6 243
IS42S32200C1
POWER-DOWN
Integrated Silicon Solution, Inc. — www.issi.com —
Rev. B
1/18/07
POWER-DOWN
Power-down occurs if CKE is registered LOW coincident
with a NOP or COMMAND INHIBIT when no accesses are
in progress. If power-down occurs when all banks are idle,
this mode is referred to as precharge power-down; if power-
down occurs when there is a row active in either bank, this
mode is referred to as active power-down. Entering power-
down deactivates the input and output buffers, excluding
CKE, for maximum power savings while in standby. The
device may not remain in the power-down state longer than
the refresh period (64ms) since no refresh operations are
performed in this mode.
The power-down state is exited by registering a NOP or
COMMAND INHIBIT and CKE HIGH at the desired clock
edge (meeting t
PRECHARGE
The PRECHARGE command (see figure) is used to
deactivate the open row in a particular bank or the open
row in all banks. The bank(s) will be available for a
subsequent row access some specified time (t
the PRECHARGE command is issued. Input A10 deter-
mines whether one or all banks are to be precharged, and
in the case where only one bank is to be precharged,
inputs BA0, BA1 select the bank. When all banks are to be
precharged, inputs BA0, BA1 are treated as “Don’t Care.”
Once a bank has been precharged, it is in the idle state and
must be activated prior to any READ or WRITE com-
mands being issued to that bank.
CKS
COMMAND
). See figure below.
CKE
CLK
All banks idle
Enter power-down mode
t
NOP
CKS
RP
Input buffers gated off
) after
1-800-379-4774
PRECHARGE Command
Exit power-down mode
BA0, BA1
A0-A9
CKE
RAS
CAS
CLK
A10
WE
CS
t
HIGH - Z
CKS
NOP
DON'T CARE
BANK ADDRESS
BANK SELECT
ACTIVE
ALL BANKS
t
t
t
RCD
RAS
RC
29