EVAL-ADXL343Z-M Analog Devices, EVAL-ADXL343Z-M Datasheet - Page 4

no-image

EVAL-ADXL343Z-M

Manufacturer Part Number
EVAL-ADXL343Z-M
Description
Acceleration Sensor Development Tools EB
Manufacturer
Analog Devices
Datasheet

Specifications of EVAL-ADXL343Z-M

Rohs
yes
Tool Is For Evaluation Of
ADXL343
Acceleration
2 g, 4 g, 8 g, 16 g
Sensing Axis
Triple Axis
Interface Type
I2C, SPI
Operating Voltage
2 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Operating Current
140 uA
Output Type
Digital
Product
Evaluation Systems
Sensitivity
256 LSB/g, 128 LSB/g, 64 LSB/g, 32 LSG/g
Factory Pack Quantity
1
ADXL343
Parameter
TEMPERATURE
WEIGHT
1
2
3
4
5
6
7
The typical specifications shown are for at least 68% of the population of parts and are based on the worst case of mean ±1 σ, except for 0 g output and sensitivity,
which represents the target value. For 0 g offset and sensitivity, the deviation from the ideal describes the worst case of mean ±1 σ.
Cross-axis sensitivity is defined as coupling between any two axes.
Bandwidth is the −3 dB frequency and is half the output data rate, bandwidth = ODR/2.
The output format for the 3200 Hz and 1600 Hz ODRs is different than the output format for the remaining ODRs. This difference is described in the Data Formatting of
Upper Data Rates section.
Output data rates below 6.25 Hz exhibit additional offset shift with increased temperature, depending on selected output data rate. Refer to the Offset Performance at
Lowest Data Rates section for details.
Self-test change is defined as the output (g) when the SELF_TEST bit = 1 (in the DATA_FORMAT register, Address 0x31) minus the output (g) when the SELF_TEST bit =
0. Due to device filtering, the output reaches its final value after 4 × τ when enabling or disabling self-test, where τ = 1/(data rate). The part must be in normal power
operation (LOW_POWER bit = 0 in the BW_RATE register, Address 0x2C) for self-test to operate correctly.
Turn-on and wake-up times are determined by the user-defined bandwidth. At a 100 Hz data rate, the turn-on and wake-up times are each approximately 11.1 ms. For
other data rates, the turn-on and wake-up times are each approximately τ + 1.1 in milliseconds, where τ = 1/(data rate).
Operating Temperature Range
Device Weight
Test Conditions/Comments
Rev. 0 | Page 4 of 36
Min
−40
Typ
30
1
Data Sheet
Max
+85
Unit
°C
mg