C8051F314R Silicon Labs, C8051F314R Datasheet - Page 165

no-image

C8051F314R

Manufacturer Part Number
C8051F314R
Description
8-bit Microcontrollers - MCU 8KB 10ADC
Manufacturer
Silicon Labs
Datasheet

Specifications of C8051F314R

Product Category
8-bit Microcontrollers - MCU
Core
8051
Data Bus Width
8 bit
Maximum Clock Frequency
25 MHz
Program Memory Size
8 KB
Data Ram Size
1.25 KB
On-chip Adc
Yes
Operating Supply Voltage
2.7 V to 3.6 V
Package / Case
LQFP-32
Mounting Style
SMD/SMT
A/d Bit Size
10 bit
A/d Channels Available
17
Data Rom Size
128 B
Interface Type
I2C, SMBus, SPI, UART
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Number Of Programmable I/os
29
Number Of Timers
5
On-chip Dac
No
Processor Series
C8051
Program Memory Type
Flash
Factory Pack Quantity
500
Supply Voltage - Max
3.6 V
Supply Voltage - Min
2.7 V
15.2. Operational Modes
UART0 provides standard asynchronous, full duplex communication. The UART mode (8-bit or 9-bit) is
selected by the S0MODE bit (SCON0.7). Typical UART connection options are shown in Figure 15.3.
15.2.1. 8-Bit UART
8-Bit UART mode uses a total of 10 bits per data byte: one start bit, eight data bits (LSB first), and one stop
bit. Data are transmitted LSB first from the TX0 pin and received at the RX0 pin. On receive, the eight data
bits are stored in SBUF0 and the stop bit goes into RB80 (SCON0.2).
Data transmission begins when software writes a data byte to the SBUF0 register. The TI0 Transmit Inter-
rupt Flag (SCON0.1) is set at the end of the transmission (the beginning of the stop-bit time). Data recep-
tion can begin any time after the REN0 Receive Enable bit (SCON0.4) is set to logic 1. After the stop bit is
received, the data byte will be loaded into the SBUF0 receive register if the following conditions are met:
RI0 must be logic 0, and if MCE0 is logic 1, the stop bit must be logic 1. In the event of a receive data over-
run, the first received 8 bits are latched into the SBUF0 receive register and the following overrun data bits
are lost.
If these conditions are met, the eight bits of data is stored in SBUF0, the stop bit is stored in RB80 and the
RI0 flag is set. If these conditions are not met, SBUF0 and RB80 will not be loaded and the RI0 flag will not
be set. An interrupt will occur if enabled when either TI0 or RI0 is set.
SPACE
MARK
BIT TIMES
BIT SAMPLING
START
BIT
Figure 15.3. UART Interconnect Diagram
D0
Figure 15.4. 8-Bit UART Timing Diagram
D1
RS-232
MCU
D2
TX
RX
Rev. 1.7
D3
RS-232
LEVEL
XLTR
OR
C8051F310/1/2/3/4/5/6/7
D4
RX
RX
TX
TX
C8051Fxxx
D5
C8051Fxxx
D6
D7
STOP
BIT
165