C8051F314R Silicon Labs, C8051F314R Datasheet - Page 203

no-image

C8051F314R

Manufacturer Part Number
C8051F314R
Description
8-bit Microcontrollers - MCU 8KB 10ADC
Manufacturer
Silicon Labs
Datasheet

Specifications of C8051F314R

Product Category
8-bit Microcontrollers - MCU
Core
8051
Data Bus Width
8 bit
Maximum Clock Frequency
25 MHz
Program Memory Size
8 KB
Data Ram Size
1.25 KB
On-chip Adc
Yes
Operating Supply Voltage
2.7 V to 3.6 V
Package / Case
LQFP-32
Mounting Style
SMD/SMT
A/d Bit Size
10 bit
A/d Channels Available
17
Data Rom Size
128 B
Interface Type
I2C, SMBus, SPI, UART
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Number Of Programmable I/os
29
Number Of Timers
5
On-chip Dac
No
Processor Series
C8051
Program Memory Type
Flash
Factory Pack Quantity
500
Supply Voltage - Max
3.6 V
Supply Voltage - Min
2.7 V
18. Programmable Counter Array
The Programmable Counter Array (PCA0) provides enhanced timer functionality while requiring less CPU
intervention than the standard 8051 counter/timers. The PCA consists of a dedicated 16-bit counter/timer
and five 16-bit capture/compare modules. Each capture/compare module has its own associated I/O line
(CEXn) which is routed through the Crossbar to Port I/O when enabled (See
Crossbar Decoder” on page 131
a programmable timebase that can select between six sources: system clock, system clock divided by four,
system clock divided by twelve, the external oscillator clock source divided by 8, Timer 0 overflow, or an
external clock signal on the ECI input pin. Each capture/compare module may be configured to operate
independently in one of six modes: Edge-Triggered Capture, Software Timer, High-Speed Output, Fre-
quency Output, 8-Bit PWM, or 16-Bit PWM (each mode is described in
Modules” on page
allowing the PCA to be clocked by a precision external oscillator while the internal oscillator drives the sys-
tem clock. The PCA is configured and controlled through the system controller's Special Function Regis-
ters. The PCA block diagram is shown in Figure 18.1
Important Note: The PCA Module 4 may be used as a watchdog timer (WDT), and is enabled in this mode
following a system reset. Access to certain PCA registers is restricted while WDT mode is enabled. See
Section 18.3
for details.
Capture/Compare
205). The external oscillator clock option is ideal for real-time clock (RTC) functionality,
Module 0
SYSCLK/12
Timer 0 Overflow
SYSCLK
External Clock/8
SYSCLK/4
ECI
Figure 18.1. PCA Block Diagram
Capture/Compare
for details on configuring the Crossbar). The counter/timer is driven by
Module 1
CLOCK
MUX
PCA
Crossbar
16-Bit Counter/Timer
Port I/O
Rev. 1.7
Capture/Compare
Module 2
C8051F310/1/2/3/4/5/6/7
Capture/Compare
Section “18.2. Capture/Compare
Module 3
Section “13.1. Priority
Capture/Compare
Module 4 / WDT
203