C8051F045R Silicon Labs, C8051F045R Datasheet - Page 98

no-image

C8051F045R

Manufacturer Part Number
C8051F045R
Description
8-bit Microcontrollers - MCU 25 MIPS 64KB 10ADC
Manufacturer
Silicon Labs
Datasheet

Specifications of C8051F045R

Product Category
8-bit Microcontrollers - MCU
Core
8051
Data Bus Width
8 bit
Maximum Clock Frequency
25 MHz
Program Memory Size
64 KB
Data Ram Size
4.25 KB
On-chip Adc
Yes
Operating Supply Voltage
2.7 V to 3.6 V
Package / Case
TQFP-64
Mounting Style
SMD/SMT
A/d Bit Size
10 bit
A/d Channels Available
13
Data Rom Size
64 KB
Interface Type
CAN, SMBus, SPI, UART
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Number Of Programmable I/os
32
Number Of Timers
16 bit
Processor Series
C8051
Program Memory Type
Flash
Factory Pack Quantity
500
Supply Voltage - Max
3.6 V
Supply Voltage - Min
2.7 V
C8051F040/1/2/3/4/5/6/7
98
Bit7:
Bit6:
Bit5:
Bit4:
Bits3-1:
Bit0:
An important note about external convert start (CNVSTR0 and CNVSTR2): If CNVSTR2 is enabled in
AD2EN
R/W
Bit7
AD2EN: ADC2 Enable Bit.
0: ADC2 Disabled. ADC2 is in low-power shutdown.
1: ADC2 Enabled. ADC2 is active and ready for data conversions.
AD2TM: ADC2 Track Mode Bit.
0: Normal Track Mode: When ADC2 is enabled, tracking is continuous unless a conversion is in
process.
1: Low-power Track Mode: Tracking defined by AD2CM2-0 bits (see below).
AD2INT: ADC2 Conversion Complete Interrupt Flag.
This flag must be cleared by software.
0: ADC2 has not completed a data conversion since the last time this flag was cleared.
1: ADC2 has completed a data conversion.
AD2BUSY: ADC2 Busy Bit.
Read:
0: ADC2 Conversion is complete or a conversion is not currently in progress. AD2INT is set to
logic 1 on the falling edge of AD2BUSY.
1: ADC2 Conversion is in progress.
Write:
0: No Effect.
1: Initiates ADC2 Conversion if AD2CM2-0 = 000b
AD2CM2-0: ADC2 Start of Conversion Mode Select.
AD2TM = 0:
000: ADC2 conversion initiated on every write of ‘1’ to AD2BUSY.
001: ADC2 conversion initiated on overflow of Timer 3.
010: ADC2 conversion initiated on rising edge of external CNVSTR2 or CNVSTR0.
011: ADC2 conversion initiated on overflow of Timer 2.
1xx: ADC2 conversion initiated on write of ‘1’ to AD0BUSY (synchronized with ADC0 software-
commanded conversions).
AD2TM = 1:
000: Tracking initiated on write of ‘1’ to AD2BUSY and lasts 3 SAR2 clocks, followed by conver-
sion.
001: Tracking initiated on overflow of Timer 3 and lasts 3 SAR2 clocks, followed by conversion.
010: ADC2 tracks only when CNVSTR2 (or CNVSTR0, See Section 7.2.1) input is logic low; con-
version starts on rising CNVSTR2 edge.
011: Tracking initiated on overflow of Timer 2 and lasts 3 SAR2 clocks, followed by conversion.
1xx: Tracking initiated on write of ‘1’ to AD0BUSY and lasts 3 SAR2 clocks, followed by conver-
sion.
AD2WINT: ADC2 Window Compare Interrupt Flag.
0: ADC2 window comparison data match has not occurred since this flag was last cleared.
1: ADC2 window comparison data match has occurred. This flag must be cleared in software.
the digital crossbar (
on page 204
CNVSTR0 is enabled in the digital crossbar and CNVSTR2 is not enabled, then CNVSTR0 may
serve as the start of conversion for both ADC0 and ADC2.
AD2TM
R/W
Bit6
SFR Definition 7.4. ADC2CN: ADC2 Control
AD2INT AD2BUSY AD2CM2 AD2CM1
), CNVSTR2 will be the external convert start signal for ADC2. However, if only
R/W
Bit5
Section “17.1. Ports 0 through 3 and the Priority Crossbar Decoder”
R/W
Bit4
Rev. 1.5
R/W
Bit3
R/W
Bit2
AD2CM0
R/W
Bit1
SFR Address:
AD2WINT 00000000
SFR Page:
R/W
Bit0
0xE8
2
Reset Value

Related parts for C8051F045R