MII Interface (continued)
Preliminary
Version: DM9161BI-12-DS-P01
July 16, 2008
TXD
CRS
CRS
TXD
TXER
synchronously with respect to TXCLK. If TXER is
asserted for one or more clock periods, and TXEN is
asserted, the PHY will emit one or more symbols that
are not part of the valid data delimiter set somewhere in
the frame being transmitted.
RXD (receive data) is a nibble (4 bits) of data that are
sampled by the reconciliation sub layer synchronously
with respect to RXCLK. For each RXCLK period which
RXDV is asserted, RXD (3:0) are transferred from the
PHY to the MAC reconciliation sub layer.
RXCLK (receive clock) output to the MAC reconciliation
sub layer is a continuous clock that provides the timing
reference for the transfer of the RXDV, RXD, and
RXER signals.
(transmit
IDLE
coding
SSD
error)
J/K
Preamble
Industrial-grade 10/100 Mbps Fast Ethernet Physical Layer Single Chip Transceiver
Preamble
transitions
SFD
SFD
are
100Base-TX
Figure 7-2
10Base-T
Data
RXDV (receive data valid) input from the PHY indicates
that the PHY is presenting recovered and decoded
nibbles to the MAC reconciliation sub layer. To interpret
a receive frame correctly by the reconciliation sub layer,
RXDV must encompass the frame, starting no later
than the Start-of-Frame delimiter and excluding any
End-Stream delimiter.
RXER (receive error) transitions are synchronously with
respect to RXCLK. RXER will be asserted for 1 or more
clock periods to indicate to the reconciliation sub layer
that an error was detected somewhere in the frame
being transmitted from the PHY to the reconciliation sub
layer.
CRS (carrier sense) is asserted by the PHY when either
the transmit or receive medium is non-idle, and
de-asserted by the PHY when the transmit and receive
medium are idle. Figure 7-2 depicts the behavior of
CRS during 10Base-T and 100Base-TX transmission.
Data
EFD
ESD
T/R
DM9161BI
IDLE
14