CMX625P4 CMLMICRO [CML Microcircuits], CMX625P4 Datasheet - Page 21

no-image

CMX625P4

Manufacturer Part Number
CMX625P4
Description
ISDN TA POTS Interface
Manufacturer
CMLMICRO [CML Microcircuits]
Datasheet
ISDN TA POTS Interface
The CMX625 is programmed via the ‘MON1’ (Monitor Channel 1) channel in TE mode and the ‘Monitor’
channel in non-TE mode. The programming sequence consists of 3 consecutive Monitor bytes: the IOM-2
address, the CMX625 command and data byte. Before executing a command, the CMX625 compares the
received IOM-2 address byte with its own address. The MSB of the IOM-2 address is always a ‘1’ (see
section 1.5.2). A logical ‘1’ in the MSB of the CMX625 command represents a write operation and a
logical ‘0’ represents a read operation.
Structure for Register read/write operations:
Example 1: Program the CMX625 to generate interrupt requests for DTMF RX Status Change on bit 5 of
C/I channel, i.e. C/I1 Channel Output Control Code (2-0)=110. Set IOM-2 address to SA2-SA0=010 and
device select, DS=1.
If the command is a register read then only the address and command bytes are sent. The CMX625 will
respond with an IOM-2 Register address byte followed by the read data. The IOM-2 Register address byte
consists of the Register address that is being read in the least significant 4 bits and the IOM-2 address
(less the device select bit) in the most significant 4 bits.
Command
(DD)
Register
MX
1
0
0
1
0
1
0
1
1
0
0
1
0
1
0
1
1
1
2001 Consumer Microcircuits Limited
IOM
(DU)
MR
1
1
0
0
1
0
1
0
1
1
0
0
1
0
1
0
1
1
0=Read
1=Write
(hex)
FF
A8
A8
FF
FF
A8
A8
FF
FF
FF
DD
88
88
06
06
89
89
20
20
R/W
(DU)
MX
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
(DD)
MR
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
(hex)
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
DU
X
Monitor Channel Idle State
Transmit IOM-2 Address
Acknowledge Address
Transmit Command (Write IOM-2 Control, $8)
Acknowledge Command/ Transmit IOM-2 Control Data
Acknowledge Data
End of Transmission
Transmit IOM-2 Address
Acknowledge Address
Transmit Command (Write Mask Register, $9)
Acknowledge Command/ Transmit IOM-2 Control Data
Acknowledge Data
End of Transmission
Idle
21
X
Register
Address
A3
Comment
Register
Address
A2
Register
Address
A1
Register
Address
CMX625
D/625/2
A0

Related parts for CMX625P4