W3E16M64S-200BC WEDC [White Electronic Designs Corporation], W3E16M64S-200BC Datasheet - Page 6

no-image

W3E16M64S-200BC

Manufacturer Part Number
W3E16M64S-200BC
Description
16Mx64 DDR SDRAM
Manufacturer
WEDC [White Electronic Designs Corporation]
Datasheet
February 2005
Rev. 4
FIGURE 3 – MODE REGISTER DEFINITION
0*
BA
* M14 and M13
(BA0 and BA1 must be
"0, 0" to select
the base mode register
(vs. the extended
mode register).
1
0*
BA
0
M12
0
0
-
A
12
Operating Mode
M11
A
0
0
-
White Electronic Designs
11
A
10
M10
0
0
-
A
9
M9
A
0
0
-
8
A
7
CAS Latency
M8
0
1
-
A
6
M7
A
0
0
-
5
A
BT
4
M3
0
1
M6-M0
Valid
Valid
A
-
3
M2
M6
Burst Length
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
A
M1
M5
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
2
M0
M4
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Operating Mode
Normal Operation
Normal Operation/Reset DLL
All other states reserved
A
1
A
Reserved
Reserved
Reserved
Reserved
Reserved
0
M3 = 0
Burst Type
Interleaved
Sequential
2
4
8
Mode Register (Mx)
Address Bus
CAS Latency
Burst Length
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
2.5
2
Reserved
Reserved
Reserved
Reserved
Reserved
M3 = 1
2
4
8
6
NOTES:
1. For a burst length of two, A1-Ai select two-data-element block; A0 selects the
2. For a burst length of four, A2-Ai select four-data-element block; A0-1 select the
3. For a burst length of eight, A3-Ai select eight-data-element block; A0-2 select the
4. Whenever a boundary of the block is reached within a given sequence above, the
EXTENDED MODE REGISTER
The extended mode register controls functions beyond
those controlled by the mode register; these additional
functions are DLL enable/disable, output drive strength,
and QFC#. These functions are controlled via the bits
shown in Figure 5. The extended mode register is
programmed via the LOAD MODE REGISTER command
to the mode register (with BA0 = 1 and BA1 = 0) and
will retain the stored information until it is programmed
again or the device loses power. The enabling of the DLL
should always be followed by a LOAD MODE REGISTER
command to the mode register (BA0/BA1 both LOW) to
reset the DLL.
The extended mode register must be loaded when all
banks are idle and no bursts are in progress, and the
controller must wait the specifi ed time before initiating
any subsequent operation. Violating either of these
requirements could result in unspecifi ed operation.
Length
Burst
starting column within the block.
starting column within the block.
starting column within the block.
following access wraps within the block.
2
4
8
White Electronic Designs Corporation • (602) 437-1520 • www.wedc.com
Starting Column
A2
TABLE 1 – BURST DEFINITION
0
0
0
0
1
1
1
1
Address
A1
A1
0
0
1
1
0
0
1
1
0
0
1
1
A0
A0
A0
0
1
0
1
1
0
1
0
1
0
1
0
1
0
Type = Sequential
W3E16M64S-XBX
0-1-2-3-4-5-6-7
1-2-3-4-5-6-7-0
2-3-4-5-6-7-0-1
3-4-5-6-7-0-1-2
4-5-6-7-0-1-2-3
5-6-7-0-1-2-3-4
6-7-0-1-2-3-4-5
7-0-1-2-3-4-5-6
Order of Accesses Within a Burst
0-1-2-3
1-2-3-0
2-3-0-1
3-0-1-2
0-1
1-0
Type = In ter leaved
0-1-2-3-4-5-6-7
1-0-3-2-5-4-7-6
2-3-0-1-6-7-4-5
3-2-1-0-7-6-5-4
4-5-6-7-0-1-2-3
5-4-7-6-1-0-3-2
6-7-4-5-2-3-0-1
7-6-5-4-3-2-1-0
0-1-2-3
1-0-3-2
2-3-0-1
3-2-1-0
0-1
1-0

Related parts for W3E16M64S-200BC