ATMEGA644PV ATMEL [ATMEL Corporation], ATMEGA644PV Datasheet - Page 207

no-image

ATMEGA644PV

Manufacturer Part Number
ATMEGA644PV
Description
8-bit Microcontroller with 16/32/64K Bytes In-System Programmable Flash
Manufacturer
ATMEL [ATMEL Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATMEGA644PV-10AQ
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATMEGA644PV-10AQR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATMEGA644PV-10AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATMEGA644PV-10AUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATMEGA644PV-10MU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATMEGA644PV-20AU
Manufacturer:
Atmel
Quantity:
10 000
19.3.3
8011D–AVR–02/07
Address Packet Format
depicted below, START and STOP conditions are signalled by changing the level of the SDA
line when the SCL line is high.
Figure 19-3. START, REPEATED START and STOP conditions
All address packets transmitted on the TWI bus are 9 bits long, consisting of 7 address bits, one
READ/WRITE control bit and an acknowledge bit. If the READ/WRITE bit is set, a read opera-
tion is to be performed, otherwise a write operation should be performed. When a Slave
recognizes that it is being addressed, it should acknowledge by pulling SDA low in the ninth SCL
(ACK) cycle. If the addressed Slave is busy, or for some other reason can not service the Mas-
ter’s request, the SDA line should be left high in the ACK clock cycle. The Master can then
transmit a STOP condition, or a REPEATED START condition to initiate a new transmission. An
address packet consisting of a slave address and a READ or a WRITE bit is called SLA+R or
SLA+W, respectively.
The MSB of the address byte is transmitted first. Slave addresses can freely be allocated by the
designer, but the address 0000 000 is reserved for a general call.
When a general call is issued, all slaves should respond by pulling the SDA line low in the ACK
cycle. A general call is used when a Master wishes to transmit the same message to several
slaves in the system. When the general call address followed by a Write bit is transmitted on the
bus, all slaves set up to acknowledge the general call will pull the SDA line low in the ack cycle.
The following data packets will then be received by all the slaves that acknowledged the general
call. Note that transmitting the general call address followed by a Read bit is meaningless, as
this would cause contention if several slaves started transmitting different data.
All addresses of the format 1111 xxx should be reserved for future purposes.
Figure 19-4. Address Packet Format
SDA
SCL
SDA
SCL
START
START
Addr MSB
1
STOP
2
START
ATmega164P/324P/644P
Addr LSB
7
REPEATED START
R/W
8
ACK
9
STOP
207