Register 64. Linefeed Control
Reset settings = 0000_0000
Name
Type
Bit
6:4
2:0
Bit
7
3
Reserved
Reserved
LFS[2:0]
LF[2:0]
Name
D7
D6
Read returns zero.
Linefeed Shadow.
This register reflects the actual realtime linefeed state. Automatic operations may cause
actual linefeed state to deviate from the state defined by linefeed register (e.g., when
linefeed equals ringing state, LFS will equal on-hook transmission state during ringing
silent period and ringing state during ring burst).
000 = Open
001 = Forward active
010 = Forward on-hook transmission
011 = TIP open
100 = Ringing
101 = Reverse active
110 = Reverse on-hook transmission
111 = RING open
Read returns zero.
Linefeed.
Writing to this register sets the linefeed state.
000 = Open
001 = Forward active
010 = Forward on-hook transmission
011 = TIP open
100 = Ringing
101 = Reverse active
110 = Reverse on-hook transmission
111 = RING open
LFS[2:0]
D5
R
Preliminary Rev. 0.5
D4
D3
Function
D2
LF[2:0]
R/W
D1
D0
Si3233