zl30102 Zarlink Semiconductor, zl30102 Datasheet - Page 28

no-image

zl30102

Manufacturer Part Number
zl30102
Description
T1/e1 Stratum 4/4e Redundant System Clock Synchronizer For Ds1/e1 And H.110
Manufacturer
Zarlink Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
zl30102QDG1
Manufacturer:
Zarlink
Quantity:
95
Part Number:
zl30102QDG1
Manufacturer:
BROADCOM
Quantity:
96
Part Number:
zl30102QDG1
Manufacturer:
ZARLINK
Quantity:
20 000
Part Number:
zl30102QDG1
0
The following is an example of how active/redundant setup can be configured.
The active timing card is set based on the desired application and is set to:
The HOLDOVER and REF_FAIL pins help evaluate quality of clocks and quality of redundant clock.
The redundant timing card is set based on desired applications and is set to:
The HOLDOVER and REF_FAIL pins help evaluate quality of clocks and quality of redundant clock.
Primary master mode, SEC_MSTR=0
Normal Mode, MODE_SEL1:0=00 (forces device to the input reference set at REF_SEL)
Automatic mode, MODE_SEL1:0=11 (allows device to auto-switch if reference fails)
Normal (manual) mode, MODE_SEL1:0=00
REF2 and REF2_SYNC as the input reference, REF_SEL1=1 (forces redundant device to lock to output
of active card)
Secondary master mode, SEC_MSTR=1
MODE_SEL1:0=11
SEC_MSTR=0
MODE_SEL1:0=00
REF_SEL1:0=10
SEC_MSTR=1
Figure 18 - Clock Redundancy with Two Independent Timing Cards
BITS 0 clock
BITS 1 clock
BITS 0 clock
BITS 1 clock
Redundant Timing Card
Active Timing Card
REF2
REF0
REF1
REF2_SYNC
REF2_SYNC
REF2
REF0
REF1
Redundant Frame Sync (optional)
Redundant Clock
Active Clock
Active Frame Sync (optional)
Zarlink Semiconductor Inc.
ZL30102
ZL30102
ZL30102
OSC
OSC
28
Output Clocks
Output Clocks
Data Sheet