pca9632 NXP Semiconductors, pca9632 Datasheet - Page 7

no-image

pca9632

Manufacturer Part Number
pca9632
Description
Pca9632 4-bit Fm I?c-bus Low Power Led Driver
Manufacturer
NXP Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
pca9632DP
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
pca9632DP1
Manufacturer:
NXP
Quantity:
42 000
Part Number:
pca9632DP1
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
pca9632DP1,118
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
pca9632DP1118
Manufacturer:
NXP Semiconductors
Quantity:
135
Part Number:
pca9632DP2
Manufacturer:
NXP
Quantity:
51 000
Part Number:
pca9632DP2
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
pca9632TK
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
pca9632TK
0
Company:
Part Number:
pca9632TK
Quantity:
6 000
Part Number:
pca9632TK2
Manufacturer:
NXP
Quantity:
30 000
Part Number:
pca9632TK2118
Manufacturer:
NXP Semiconductors
Quantity:
135
NXP Semiconductors
PCA9632_1
Objective data sheet
Table 3.
Remark: Other combinations not shown in
reserved and must not be used for proper device operation.
AI[2:0] = 000 is used when the same register must be accessed several times during a
single I
is overwritten each time the register is accessed during a write operation.
AI[2:0] = 100 is used when all the registers must be sequentially accessed, for example,
power-up programming.
AI[2:0] = 101 is used when the four LED drivers must be individually programmed with
different values during the same I
setting to another color setting.
AI[2:0] = 110 is used when the LED drivers must be globally programmed with different
settings during the same I
blinking change.
AI[2:0] = 111 is used when individual and global changes must be performed during the
same I
same time.
Only the 4 least significant bits D[3:0] are affected by the AI[2:0] bits.
When the Control register is written, the register entry point determined by D[3:0] is the
first register that will be addressed (read or write operation), and can be anywhere
between 0000 and 1100 (as defined in
is set and the rollover value at which the point where the register increment stops and
goes to the next one is determined by AI[2:0]. See
example, if the Control register = 1110 1000 (E8h), then the register addressing sequence
will be (in hex):
08
as the master keeps sending or reading data.
AI2
0
1
1
1
1
2
2
C-bus communication, for example, changing a color and global brightness at the
AI1
0
0
0
1
1
C-bus communication, for example, changes the brightness of a single LED. Data
Auto-Increment options
0C
AI0
0
0
1
0
1
00
Rev. 01 — 28 September 2007
Function
no Auto-Increment
Auto-Increment for all registers. D3, D2, D1, D0 roll over to ‘0000’ after
the last register (1100) is accessed.
Auto-Increment for individual brightness registers only. D3, D2, D1, D0
roll over to ‘0010’ after the last register (0101) is accessed.
Auto-Increment for global control registers only. D3, D2, D1, D0 roll over
to ‘0110’ after the last register (0111) is accessed.
Auto-Increment for individual and global control registers only. D3, D2,
D1, D0 roll over to ‘0010’ after the last register (0111) is accessed.
2
C-bus communication, for example, global brightness or
07
2
C-bus communication, for example, changing color
02
Table
Table 3
4). When AI[2] = 1, the Auto-Increment flag
4-bit Fm+ I
07
Table 3
(AI[2:0] = 001, 010, and 011) are
02
2
for rollover values. For
C-bus low power LED driver
07
PCA9632
© NXP B.V. 2007. All rights reserved.
02
… as long
7 of 32

Related parts for pca9632