AD9516-5 Analog Devices, Inc., AD9516-5 Datasheet - Page 61

no-image

AD9516-5

Manufacturer Part Number
AD9516-5
Description
14-output Clock Generator
Manufacturer
Analog Devices, Inc.
Datasheet
Reg.
Addr
(Hex) Bit(s) Name
01D
01F
01F
01F
01F
01F
01F
Reg.
Addr
(Hex) Bit(s) Name
0A0
0A1
Table 50. Fine Delay Adjust: OUT6 to OUT9
[0]
[5]
[4]
[3]
[2]
[1]
[0]
[0]
[5:3] OUT6 ramp
Holdover
enable
Holdover
active
REF2
selected
CLK
frequency >
threshold
REF2
frequency >
threshold
REF1
frequency >
threshold
Digital lock
detect
OUT6 delay
bypass
capacitors
Along with 0x01D[2] enables the holdover function.
[0] = 1; holdover enabled.
Readback register: indicates if the part is in the holdover state (see Figure 40). This is not the same as
holdover enabled.
[5] = 0; not in holdover.
[5] = 1; holdover state active.
Readback register: indicates which PLL reference is selected as the input to the PLL.
[4] = 0; REF1 selected (or differential reference if in differential mode).
[4] = 1; REF2 selected.
Readback register: indicates if the CLK frequency is greater than the threshold (see Table 13, REF1, REF2, and
CLK frequency status monitor).
[3] = 0; CLK frequency is less than the threshold.
[3] = 1; CLK frequency is greater than the threshold.
Readback register: indicates if the frequency of the signal at REF2 is greater than the threshold frequency
set by Register 0x01A[6].
[2] = 0; REF2 frequency is less than threshold frequency.
[2] = 1; REF2 frequency is greater than threshold frequency.
Readback register: indicates if the frequency of the signal at REF2 is greater than the threshold frequency
set by Register 0x01A[6].
[1] = 0; REF1 frequency is less than threshold frequency.
[1] = 1; REF1 frequency is greater than threshold frequency.
Readback register: digital lock detect.
[0] = 0; PLL is not locked.
[0] = 1; PLL is locked.
Description
[0] = 0; holdover disabled (default).
Description
Bypass or use the delay function.
[0] = 0; use delay function.
[0] = 1; bypass delay function (default).
Selects the number of ramp capacitors used by the delay function. The combination of the number of
capacitors and the ramp current sets the full-scale delay.
[5] [4] [3] Number of Capacitors
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
4 (default)
3
3
2
3
2
2
1
Rev. 0 | Page 61 of 76
AD9516-5