REGISTER MAP DESCRIPTIONS
Table 48 through Table 57 provide a detailed description of each of the control register functions. The registers are listed by hexadecimal
address. Reference to a specific bit or range of bits within a register is indicated by the brackets. For example, [3] refers to Bit 3, and [5:2]
refers to the range of bits from Bit 5 through Bit 2.
Table 48. Serial Port Configuration
Reg. Addr (Hex)
000
000
000
000
000
004
Bit(s)
[7]
[6]
[5]
[4]
[3:0]
[0]
Name
SDO active
LSB first
Soft reset
Long instruction
Mirror [7:4]
Read back active registers
Description
Selects unidirectional or bidirectional data transfer mode.
[7] = 0; SDIO pin used for write and read; SDO set high impedance;
bidirectional mode (default).
[7] = 1; SDO used for read; SDIO used for write; unidirectional mode.
MSB or LSB data orientation.
[6] = 0; data-oriented MSB first; addressing decrements (default).
[6] = 1; data-oriented LSB first; addressing increments.
Soft reset.
[5] = 1 (not self-clearing). Soft reset; restores default values to internal registers.
Not self-clearing. Must be cleared to 0b to complete reset operation.
Short/long instruction mode (this part uses long instruction mode only, so this bit
should always be = 1).
[4] = 0; 8-bit instruction (short).
[4] = 1; 16-bit instruction (long) (default).
Bits[3:0] should always mirror [7:4] so that it does not matter whether the part
is in MSB or LSB first mode (see Register 0x000[6]). User should set bits as follows:
[0] = [7].
[1] = [6].
[2] = [5].
[3] = [4].
Select register bank used for a readback.
[0] = 0; read back buffer registers (default).
[0] = 1; read back active registers.
Rev. 0 | Page 54 of 76