KSC-1000 Kodak, KSC-1000 Datasheet - Page 37

no-image

KSC-1000

Manufacturer Part Number
KSC-1000
Description
Timing Generator Full Program-ability Through a Simple 3-wire Serial Interface Allows Maximum Flexibility in Sensor Operation.
Manufacturer
Kodak
Datasheet
IMAGE SENSOR SOLUTIONS
37
Status Register
The Status Register is a read only register which provides DLL, Frame Table, Line Table, and VD
status.
K S C - 1 0 0 0 R e v 1 . 0
Register 10
Data Length
13 bits
7 bits
8 bits
1 bit
1 bit
1bit
w w w . k o d a k . c o m / g o / i m a g e r s
DLL Locked, 0 = DLL not locked, 1 = DLL locked
Current Frame Table Address
Current Line Table Address
VD Registered, 0 = VD not registered, 1 = VD registered
VD Wait 0 = not currently waiting for VD, 1 = waiting for VD
Line Counter Value
Table 28 Status Register Map
5 8 5 - 7 2 2 - 4 3 8 5
Status Register
Description
E m a i l : i m a g e r s @ k o d a k . c o m
Default
Decimal
NA
NA
NA
NA
NA
NA