KSC-1000 Kodak, KSC-1000 Datasheet - Page 33

no-image

KSC-1000

Manufacturer Part Number
KSC-1000
Description
Timing Generator Full Program-ability Through a Simple 3-wire Serial Interface Allows Maximum Flexibility in Sensor Operation.
Manufacturer
Kodak
Datasheet
IMAGE SENSOR SOLUTIONS
33
Bit Location
K S C - 1 0 0 0 R e v 1 . 0
Bit Location
3:4
0:3
4:6
0
1
2
5
6
7
8
w w w . k o d a k . c o m / g o / i m a g e r s
Data Length
Register 8
34 bits
Horizontal Binning
7 bits
Table Number One of 8 possible frame tables (7:0). Any given sensor operational mode has 1 or
Entry Number One of 16 possible entries (15:0). Each entry points to a line table to define the
HCLK_V Enable
FRAME_VALID
Video Amplifier
Increment Line
Force Shutter
LINE_VALID
Name
Check and
Clear Line
Name
Counter
Counter
Enable
Enable
E
Factor
bl
Table 20 Frame Table Access Register Map
Table 21 Frame Table Address Descriptor
vertical clocking interval.
more frame tables associated with it.
0 = do not increment the line counter or enable comparison to the Integrate
Start Line Register,
1 = increment the line counter and enable comparison to the Integrate Start
Line Register.
The comparison occurs prior to the increment.
0 = do not clear the line counter, 1 = clear the line counter
0 = SHUTTER assertion occurs only if the Check and Increment Line Counter
bit is set AND the Line Counter value matches the value programmed in the
Shutter Start Line Register.
1 = Assert SHUTTER as defined in the Shutter Start Setup Register at the
beginning of the line, regardless of the Line Counter Value and the state of the
Check Increment Line Counter bit
00 = No Binning, 1 RG clock and A/D clock per horizontal clock
01 = 1 RG clock and A/D clock per every 2 horizontal clocks
10 = 1 RG clock and AD clock per every 3 horizontal clocks
11 = 1 RG clock and AD clock per every 4 horizontal clocks
0 = Disable HCLCK generation during VCLK interval
1 = Allow HCLK generation during VCLK interval
0 = De-assert LINE_VALID
1 = Allow LINE_VALID to run as specified in the General Setup Register
0 = De-assert FRAME_VALID
1 = Assert FRAME_VALID; directly controls output pin
0 = De-assert AMP_ENABLE,
Frame Table Address
Frame Table Data
Frame Table Address Descriptor
Frame Table Access Register
Frame Table Data Descriptor
5 8 5 - 7 2 2 - 4 3 8 5
Register Field
E m a i l : i m a g e r s @ k o d a k . c o m
Description
Description
(Decimal)
Default
0
0

Related parts for KSC-1000