KSC-1000 Kodak, KSC-1000 Datasheet - Page 35

no-image

KSC-1000

Manufacturer Part Number
KSC-1000
Description
Timing Generator Full Program-ability Through a Simple 3-wire Serial Interface Allows Maximum Flexibility in Sensor Operation.
Manufacturer
Kodak
Datasheet
IMAGE SENSOR SOLUTIONS
35
Count
K S C - 1 0 0 0 R e v 1 . 0
Horizontal Binning Factor
>0
>0
0
0
0
0
0
Flag
w w w . k o d a k . c o m / g o / i m a g e r s
0
0
0
1
1
0
1
00
01
10
11
VD Event
X
X
X
0
1
0
1
Table 24 Horizontal Binning Factor Descriptor
Address(3)
Frame Table
Address (3)
Address (3)
Address (3)
No Binning, 1 RG clock and A/D clock per horizontal clock
1 RG clock and A/D clock per every 2 horizontal clocks
1 RG clock and AD clock per every 3 horizontal clocks
1 RG clock and AD clock per every 4 horizontal clocks
Line Table
Line Table
Line Table
Entry (3)
Table 23 Frame Table Event Descriptor
0
1
1
Frame Table Event Descriptor
Address(2:0)
Address (2:0)
Address (2:0)
Address (2:0)
Frame Table
Frame Table
Frame Table
Frame Table
5 8 5 - 7 2 2 - 4 3 8 5
Line Table
Line Table
Line Table
Entry (2:0)
Address
Address
Address
Mnemonic
JMPFT
INCVD
BRVD
WVD
INCZ
E m a i l : i m a g e r s @ k o d a k . c o m
Description
INC
ELT
Jump to entry 0 of the frame table
indicated in the Address(2:0)field.
Go to next line in the current frame
table.
Jump to entry 0 of the frame table
indicated in the Address(2:0)field.
Execute line table indicated in the
Address(3;0) field indefinitely until a
VD event occurs.
Complete execution of the Line Table
indicated in the Address(3:0) field.
Go to the next frame table entry when
completed.
Execute the Line Table indicated in
the Address(3:0) field the number of
times indicated in the Count field.
Jump to the next frame table entry
when completed.
Jump to frame table entry pointed to
by the Address field.
Decrement the count variable.
If the count variable > 0 jump to frame
table entry pointed to by the Address
field.
Go to the next frame table entry when
Count variable count = 0.
Note: Nesting of INCZ instructions is
not supported.
Store Count as a variable.
Action

Related parts for KSC-1000