ADAM24P08 ETC, ADAM24P08 Datasheet - Page 35

no-image

ADAM24P08

Manufacturer Part Number
ADAM24P08
Description
Remote Control Transmitter
Manufacturer
ETC
Datasheet
www.DataSheet.co.kr
ADAM24PXX
(38) SO
(38) RO
<Comment>
<Comment>
Naming :
Status :
Format :
Function :
<Purpose>
Naming :
Status :
Format :
Function :
<Purpose>
Set Output Register Latch
Set
D(Y) ← 1
REMOUT ← 1(PMR=5)
D0~D9 ← 1 (High-Z)
R(Y) ← 1
R(Y) ← 1
D0~D9, R2~R3 ← 1
A single D output line is set to logic 1, if data of Y-register is
between 0 to 7.
Carrier frequency come out from REMOUT port, if data of
Y-register is 8.
All D output line is set to logic 1, if data of Y-register is 9.
When Y is between Ch and Dh, one of R2 and R3 is set to logic 1.
When Y is Eh, R2 and R3 is set to logic 1.
When Y is Fh, All D output and R2 and R3 is set to logic 1.
Data of Y-register is between 0 to 7, selects appropriate D output.
Data of Y-register is 8, selects REMOUT port.
Data of Y-register is 9, selects all D port.
Data in Y-register, when between Ch and Dh, selects an appropriate R port.
Data in Y-register, when it is Fh, selects all of D0~D9 and R2~R3.
Set Output Register Latch
Set
D(Y) ← 0
REMOUT ← 0(PMR=5)
D0~D9 ← 0
R(Y) ← 0
R(Y) ← 0
D0~D9,R2~R3 ← 0
A single D output line is set to logic 0, if data of Y-register is
between 0 to 7.
REMOUT port is set to logic 0, if data of Y-register is 8.
All D output line is set to logic 0, if data of Y-register is 9.
When Y is between Ch and Dh, one of R2 and R3 is set to logic 0.
When Y is Eh, R2 and R3 is set to logic 0.
When Y is Fh, All D output and R2 and R3 is set to logic 0.
Data of Y-register is between 0 to 7, selects appropriate D output.
Data of Y-register is 8, selects REMOUT port.
Data of Y-register is 9, selects all D port.
Data in Y-register, when between Ch and Dh, selects an appropriate R port.
Data in Y-register, when it is Fh, selects all of D0~D9 and R2~R3.
Data in Y-register, when it is Eh, selects all of R2~R3.
Data in Y-register, when it is Eh, selects all of R2~R3.
Page 34 of 36
Y = 9
Ch ≤ Y ≤ Dh
Y = Eh
Y = Fh
Y = 9
Ch ≤ Y ≤ Dh
Y = Eh
Y = Fh
0 ≤ Y ≤ 7
Y = 8
0 ≤ Y ≤ 7
Y = 8
3. Instruction
Datasheet pdf - http://www.DataSheet4U.net/

Related parts for ADAM24P08