3. Instruction
Note) i = 0~f, n = 0~3, a = 6bit PC Address
*1 Column ST indicates conditions for changing status. Symbols have the following
*2 Refer to 2.14. Port Operation.
meanings
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
S : On executing an instruction, status is unconditionally set.
C : Status is only set when carry or borrow has occurred in operation.
B : Status is only set when borrow has not occurred in operation.
E : Status is only set when equality is found in comparison.
N : Status is only set when equality is not found in comparison.
Z : Status is only set when the result is zero.
Comparison
Category
Arithmetic
Control
Output
Input /
Mnemonic
EORM
WDTR
NEGA
MNEZ
YNEI i
ALEM
ALEI i
YNEA
STOP
NOP
LAK
LAR
LPY
RO
DY
SO
Page 21 of 36
Y ← Y - 1
A ← A + M (X,Y)
A ← A + 1
TEST A ≤ M(X,Y)
TEST A ≤ i
TEST M(X,Y) ≠ 0
TEST Y ≠ A
TEST Y ≠ i
A ← K
A ← R
Output(Y) ← 1
Output(Y) ← 0
Watch Dog Timer Reset
Stop operation
PMR ← Y
No operation
*2
*2
Function
ADAM24PXX
ST
B
N
N
N
S
Z
E
E
S
S
S
S
S
S
S
S
*1