P6002ZC Teccor Electronics, Inc., P6002ZC Datasheet - Page 100

no-image

P6002ZC

Manufacturer Part Number
P6002ZC
Description
275 V, four-port longitudinal two-chip protector
Manufacturer
Teccor Electronics, Inc.
Datasheet
High Speed Transmission Equipment
Figure 3.14 Pair Gain COT Protection
http://www.teccor.com
+1 972-580-7777
Ring2
Central Office Terminal (COT) Interface
Ring1
Tip2
Tip1
Protection Circuitry
Longitudinal protection is required at the Central Office Terminal (COT) interface because of
the ground connection used with loop powering. (Figure 3.14) Two P1800SC MC SIDACtor
devices provide overvoltage protection and two F1250T TeleLink fuses (one on Tip, one on
Ring) provide overcurrent protection. For the U-interface side of the coupling transformer,
the illustration shows the P0080SA MC SIDACtor device used for additional overvoltage
protection.
For Customer Premises (CP) and Remote Terminal (RT) interfaces where an earth ground
connection is not used, only metallic protection is required. Figure 3.15 shows metallic
protection satisfied using a single P3100SC MC across Tip and Ring and a single F1250T
on either Tip or Ring to satisfy metallic protection.
U-Interface
P0080SA
3 - 12
Power
Source
SIDACtor
P1800SC MC
P1800SC MC
®
Data Book and Design Guide
© 2002 Teccor Electronics
F1250T
F1250T
Ring
Tip

Related parts for P6002ZC