TMP89xy60UG/FG Toshiba, TMP89xy60UG/FG Datasheet - Page 422

no-image

TMP89xy60UG/FG

Manufacturer Part Number
TMP89xy60UG/FG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMP89xy60UG/FG

Package
LQFP64/QFP64
Rom Types (m=mask,p=otp,f=flash)
M/F
Rom Size
32/60
Ram Size
3K
Driver Led
8
Driver Lcd
-
Spi/sio Channels
-
Uart/sio Channels
2
I2c/sio Channels
1
High-speed Serial Output
-
Adc 8-bit Channels
-
Adc 10-bit Channels
16
Da Converter Channels
-
Timer Counter 18-bit Channel
-
Timer Counter 16-bit Channel
2
Timer Counter 8-bit Channel
4
Motor Channels
-
Watchdog Timer
Y
Dual Clock
Y
Clock Gear
Y
Number Of I/o Ports
58
Power Supply (v)
4.3 to 5.5
25.5
Power-on Reset Circuit Characteristics
RA004
25.5
Note 6: When the supply voltage VDD is less than 3.0V, the operating temperature Topr must be in a range of −20°C to 85°C.
Note:Care must be taken in system designing since the power-on reset circuit may not fulfill its functions due to the
Note 1: Because the power-on reset releasing voltage and the power-on reset detecting voltage change relative to one another,
Note 2: A clock output by an oscillating circuit is used as the input clock for a warming-up counter. Because the oscillation fre-
Note 3: Boost the power supply voltage such that t
Power-on Reset Circuit Characteristics
Power supply voltage (V
CPU and peripheral circuit
reset signal
V
Symbol
V
t
Warm-up counter clock
fluctuations in the power supply voltage (V
t
t
PROFF
PROFF
PRON
t
PWUP
t
Power-on reset signal
PRON
PRW
VDD
the detected voltage will never become inverted.
quency does not stabilize until an oscillating circuit stabilizes, some errors may be included in the warming-up time.
Operating voltage
V
Power-on reset releasing voltage
Power-on reset detecting voltage
Power-on reset releasing response time
Power-on reset detecting response time
Power-on reset minimum pulse width
Warming-up time after a reset is cleared
Power supply rise time
V
PROFF
PRON
DD
)
Figure 25-6 Power-on Reset Operation Timing
Warm-up counter start
t
VDD
Parameter
t
PWUP
Note
Note
DD
).
VDD
Page 406
becomes smaller that t
Min.
2.2
2.0
1.0
t
PRON
102 x 2
PWUP
Typ.
0.01
0.01
2.4
2.2
t
PPW
9
/fc
.
t
PROFF
(V
SS
Max.
=0 V, Topr = −40 to 85°C)
2.6
2.3
0.1
0.1
5
TMP89FS60
Unit
ms
ms
V
s