AD9122 Analog Devices, AD9122 Datasheet - Page 35

no-image

AD9122

Manufacturer Part Number
AD9122
Description
Manufacturer
Analog Devices
Datasheet

Specifications of AD9122

Resolution (bits)
16bit
Dac Update Rate
1.23GSPS
Dac Settling Time
n/a
Max Pos Supply (v)
+3.47V
Single-supply
No
Dac Type
Current Out
Dac Input Format
LVDS,Par

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD9122AXCPZ
Manufacturer:
ADI
Quantity:
250
Part Number:
AD9122BCPZ
Manufacturer:
VISHAY
Quantity:
15 000
Part Number:
AD9122BCPZ
Manufacturer:
ADI
Quantity:
852
Part Number:
AD9122BCPZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
AD9122BCPZ
Quantity:
737
Part Number:
AD9122BCPZ-ND
Manufacturer:
ADI
Quantity:
31
Part Number:
AD9122BCPZRL
Manufacturer:
ARTESYN
Quantity:
125
FRAME Initiated Absolute FIFO Reset
In FIFO rate synchronization mode, the write pointer of the FIFO
is reset in an absolute manner. The synchronization signal aligns
the internal clocks on the part to a common reference clock so
that the pipeline delay in the digital circuit stays the same during
power cycles. The synchronization signal is sampled by the DAC
clock in the AD9122. The edge of the DAC clock used to sample
the synchronization signal is selected by Bit 3 of Register 0x10.
The FRAME signal is used to reset the FIFO write pointer. In
the FIFO rate synchronization mode, the FIFO write pointer is
reset immediately after the FRAME signal is asserted high for at
least the time interval required to load complete data to the I
and Q DACs. The FIFO write pointer is reset to the value of the
FIFO Phase Offset[2:0] bits in Register 0x17. FIFO rate synchro-
nization is selected by setting Bit 6 of Register 0x10 to 0.
POINTER
POINTER
FRAME
WRITE
READ
SYNC
Figure 49. FRAME Input vs. Write Pointer Value, FIFO Rate Mode
FIFO READ RESET
0
6
FIFO WRITE
RESET
1
5
2
6
FIFO PHASE OFFSET[2:0]
REG 0x17[2:0] = 101
3
7
4
0
5
1
6
2
7
3
0
4
1
5
2
6
3
7
Rev. B | Page 35 of 60
Monitoring the FIFO Status
The FIFO initialization and status can be read from Register 0x18.
This register provides information about the FIFO status and
whether the initialization was successful. The MSB of Register 0x18
is a FIFO warning flag that can optionally trigger a device IRQ .
This flag indicates that the FIFO is close to emptying (FIFO
level is 1) or overflowing (FIFO level is 7). In this case, data
may soon be corrupted, and action should be taken.
The FIFO data level can be read from Register 0x19 at any time.
The serial port reported FIFO data level is denoted as a 7-bit
thermometer code (Base 1 code) of the write counter state
relative to the absolute read counter being at 0. The optimum
FIFO data level of 4 is therefore reported as a value of 00001111
in the status register.
Note that, depending on the timing relationship between the
DCI and the main DACCLK, the FIFO level value can be off
by a ±1 count, that is, the readback of Register 0x19 can be
00011111 in the case of a +1 count and 00000111 in the case of
a −1 count. Therefore, it is important to keep the difference
between the read and write pointers to a value of at least 2.