HSP50210JC-52 Intersil, HSP50210JC-52 Datasheet - Page 41

no-image

HSP50210JC-52

Manufacturer Part Number
HSP50210JC-52
Description
Digital Costas Loop 84-Pin PLCC
Manufacturer
Intersil
Datasheet

Specifications of HSP50210JC-52

Package
84PLCC
Power Supply Type
Analog
Typical Supply Current
225 mA
Typical Operating Supply Voltage
5 V
Minimum Operating Supply Voltage
4.75 V
Maximum Operating Supply Voltage
5.25 V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HSP50210JC-52
Manufacturer:
NS
Quantity:
6 248
Part Number:
HSP50210JC-52
Manufacturer:
GALVANTECH
Quantity:
9
Part Number:
HSP50210JC-52
Manufacturer:
INTERSIL
Quantity:
20 000
POSITION
31-16
12-9
BIT
8-5
15
14
13
4
3
2
1
0
Not Used
Reserved
False Lock Detect
Enable
Frequency Sweep
Mode
Verify State Length
False Lock Sweep
Lock Detector Control
Microprocessor
Acquisition/Track
Select
Microprocessor Lock
Reserved
Microprocessor
Frequency Sweep
Enable
FUNCTION
41
TABLE 38. ACQUISITION/TRACKING CONTROL REGISTER
No programming required.
Set to 0 for proper operation.
This bit enables the false lock detection during the verify state of state machine controlled acquisition.
The overflow of the False Lock Accumulator before the Integration Counter forces the false lock state. If
disabled, the overflow of the False Lock Accumulator has no effect on state machine operation.
0 = Disable False Lock.
1 = Enable False Lock.
Note: The false Lock Detector is designed for false lock detection on square wave data. For shaped
waveforms false lock detection should be disabled or frequency error should be used.
This bit selects whether stepped or continuous frequency sweep mode is used (see “Lock Detector” on
page 23).
0 = Stepped Frequency Sweep (provided for microprocessor controlled acquisition mode).
1 = Continuous Frequency Sweep.
These bits set the number of integration cycles over which carrier lock must be maintained before the
Lock State is declared. The verify state is used to make sure that lock detection was not the result of noise
or false lock. The 4-bit value programmed here sets the verify state from 0 to 15 Integration Periods.
These bits set the duration of forced frequency sweep before returning to the acquisition state. When
continuous frequency sweep mode is selected, the programmed number represents the number of Lock
Accumulator integration cycles to sweep before returning to the acquisition state. In stepped frequency
sweep mode, the number represents the number of loop filter compute cycles over which to enable the
sweep input to the lag accumulator.
This bit selects whether the acquisition/tracking process is controlled externally by a microprocessor or
internally by the state machine. If microprocessor control is chosen, the lock detect accumulator
integrates for the programmed period of time and ignores accumulator roll over, if any. The Lock Detector
Accumulator halts after each Integration Period and waits to be restarted by the microprocessor. In
addition, the microprocessor must select the acquisition/tracking parameters, as well as enable the
Frequency Sweep Block.
0 = Microprocessor Control.
1 = Internal State Machine Control.
0 = Track Parameters Chosen.
1 = Acquisition Parameters Chosen.
This bit controls the state of the lock bit (STATUS6) in the status output STATUS6-0 (see “Output
Selector” on page 26). In addition, this bit sets the internal state machine to the locked state when Lock
Detector Control is switched from microprocessor control to state machine control. See Table 47 for the
STATUS bit information.
Set to zero for proper operation.
This bit is used to enable the output of the Frequency Sweep Block to the lag path of the Symbol Tracking
Loop Filter. This bit is only used under microprocessor control of the Lock Detector.
DESTINATION ADDRESS = 23
HSP50210
DESCRIPTION
July 2, 2008
FN3652.5

Related parts for HSP50210JC-52