M29F010B70N6 Micron Technology Inc, M29F010B70N6 Datasheet - Page 14

no-image

M29F010B70N6

Manufacturer Part Number
M29F010B70N6
Description
Manufacturer
Micron Technology Inc
Datasheet

Specifications of M29F010B70N6

Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29F010B70N6
Manufacturer:
ST
Quantity:
3 000
Part Number:
M29F010B70N6
Manufacturer:
ST
Quantity:
3 000
Part Number:
M29F010B70N6
Manufacturer:
PHILIPS
Quantity:
2 022
Part Number:
M29F010B70N6
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29F010B70N6
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29F010B70N6
Manufacturer:
ST
0
Part Number:
M29F010B70N6
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
M29F010B70N6
Quantity:
65 832
Company:
Part Number:
M29F010B70N6
Quantity:
65 832
Company:
Part Number:
M29F010B70N6
Quantity:
683
Part Number:
M29F010B70N6-5BS2M
Manufacturer:
NS
Quantity:
304
Part Number:
M29F010B70N6-5BS2M
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29F010B70N6-5BS2M
Manufacturer:
ST
0
Part Number:
M29F010B70N6E
Manufacturer:
ST
Quantity:
20 000
Command interface
4
4.1
4.2
14/35
Command interface
All Bus Write operations to the memory are interpreted by the Command Interface.
Commands consist of one or more sequential Bus Write operations. Failure to observe a
valid sequence of Bus Write operations will result in the memory returning to Read mode.
The long command sequences are imposed to maximize data security.
The commands are summarized in
the text descriptions below.
Read/Reset command
The Read/Reset command returns the memory to its Read mode where it behaves like a
ROM or EPROM. It also resets the errors in the Status Register. Either one or three Bus
Write operations can be used to issue the Read/Reset command.
If the Read/Reset command is issued during a Block Erase operation or following a
Programming or Erase error then the memory will take upto 10
period no valid data can be read from the memory. Issuing a Read/Reset command during a
Block Erase operation will leave invalid data in the memory.
Auto Select command
The Auto Select command is used to read the Manufacturer code, the Device code and the
Block Protection status. Three consecutive Bus Write operations are required to issue the
Auto Select command. Once the Auto Select command is issued the memory remains in
Auto Select mode until another command is issued.
From the Auto Select mode the Manufacturer code can be read using a Bus Read operation
with A0 = V
Manufacturer code for STMicroelectronics is 20h.
The Device code can be read using a Bus Read operation with A0 = V
other address bits may be set to either V
20h.
The Block Protection status of each block can be read using a Bus Read operation with A0
= V
may be set to either V
Data Inputs/Outputs, otherwise 00h is output.
IL
, A1 = V
IL
IH
and A1 = V
, and A14-A16 specifying the address of the block. The other address bits
IL
or V
IL
. The other address bits may be set to either V
IH
. If the addressed block is protected then 01h is output on the
Table 4:
IL
or V
Commands. Refer to
IH
. The Device code for the M29F010B is
µs
Table 4
to abort. During the abort
IH
in conjunction with
and A1 = V
IL
or V
IH
M29F010B
. The
IL
. The