ICS1522M IDT, Integrated Device Technology Inc, ICS1522M Datasheet - Page 8

ICS1522M

Manufacturer Part Number
ICS1522M
Description
Manufacturer
IDT, Integrated Device Technology Inc
Type
Programmable PLL Frequency Synthesizerr
Datasheet

Specifications of ICS1522M

Number Of Elements
1
Supply Current
15mA
Pll Input Freq (min)
5MHz
Pll Input Freq (max)
20MHz
Operating Supply Voltage (typ)
5V
Operating Temp Range
0C to 70C
Package Type
SOIC
Output Frequency Range
Up to 230MHz
Operating Supply Voltage (min)
4.75V
Operating Supply Voltage (max)
5.25V
Operating Temperature Classification
Commercial
Pin Count
24
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICS1522M
Manufacturer:
ICS
Quantity:
4
Part Number:
ICS1522M
Manufacturer:
ICS
Quantity:
1 000
Part Number:
ICS1522M
Manufacturer:
ICS
Quantity:
1 000
Part Number:
ICS1522M
Manufacturer:
ICS
Quantity:
20 000
Part Number:
ICS1522MLF
Manufacturer:
ICS
Quantity:
4 492
Part Number:
ICS1522MLF
Manufacturer:
ICS
Quantity:
20 000
Company:
Part Number:
ICS1522MLF
Quantity:
43
Part Number:
ICS1522MTR
Manufacturer:
RENESAS
Quantity:
1 000
REG#
6
6
6
6
6
6
6
6
ICS1522
BIT(S)
3
4
5
6
7
8
9
10
BIT REF.
OMUX1
OMUX2
OMUX3
OMUX4
DACRST
AUXEN
AUXCLK
EXTREF
DESCRIPTION
OUT1 Select (Default=0)
OUT2 Select (Default=0)
OUT3 Select (Default=0)
OUT4 Select (Default=1)
0=Load Counter Output 1=Diff.
Output Divided by 4 at 0 Degrees
OUT1 will track OMUX1 when AUXEN=1
0=Internal Feedback Pulse 1=Diff.
Output Divided by 4 at 90 Degrees
OUT2 will track OMUX2 when AUXEN=1\
0=Feedback Sync Pulse LO
1=Diff. Output Divided by 4 at 180
Degrees OUT3 will track OMUX3 when AUXEN=1
0=Feedback Sync Pulse HI
1=Diff. Output Divided by 4 at 270 Degrees
OUT4 will track OMUX4 when AUXEN=1
Output Reset (Default=0)
When set to one, the CLK+ output is
kept high and the CLK-output is kept low. When returned to zero,
the CLK+ and CLK-outputs will resume toggling on a rising edge
of the OUT1 output (programmed for Load Counter) within +/- 1
clock period.
Output Test Mode (Default=0)
0=Normal Output Operation
1=Output Test Mode (see OMUX1-4 and AUXCLK)
Output Clock when in Test Mode (Default=0)
CLK+ and CLK- will track AUXCLK when AUXEN=1
XTAL/EXTREF Input Buffer (Default=0)
0=Crystal Input Operation
1=External Reference Input Operation
8