2306-VS KEITHLEY, 2306-VS Datasheet - Page 8

58T8427

2306-VS

Manufacturer Part Number
2306-VS
Description
58T8427
Manufacturer
KEITHLEY
Datasheet

Specifications of 2306-VS

No. Of Outputs
2
Output Voltage
15V
Output Voltage 2
15V
Output Current
5A
Output Current 2
5A
Load Regulation
0.01%
Length
411mm
Width
213mm
Height
89mm
Weight
3.9kg
Power Supply Output Type
Variable
Input Voltage
100VAC To 120VAC / 220VAC To 240VAC
Power Rating
50W
2306-VS
ISOLATION (LOW–EARTH): 22VDC max. Do not exceed 60VDC between any two terminals
NET WEIGHT: 3.9kg (8.6 lbs.).
SHIPPING WEIGHT: 6.4kg (14 lbs.).
INPUT POWER: 100–120VAC/220–240VAC, 50 or 60Hz (auto detected at power-up).
POWER CONSUMPTION: 165VA max.
EMC: Conforms with European Union Directive directive 89/336/EEC, EN 61326.
SAFETY: Conforms with European Union Directive 73/23/EEC, EN 61010-1.
VIBRATION: MIL-PRF-28800F Type III, Class 3.
PROGRAMMING: IEEE-488.2 (SCPI).
USER-DEFINABLE POWER-UP STATES: 3.
REAR PANEL CONNECTORS: Two trigger in and two trigger out (BNC) connectors. Two
TRIGGER IN/OUT CONNECTORS: IN High 3–5V, IN Low ≤0.8V, OUT High >4V, OUT Low
TEMPERATURE COEFFICIENT (outside 23°C ±5°C): Derate accuracy specification by
OPERATING TEMPERATURE: 0° to 50°C (derate to 70%). 0° to 35°C (full power).
STORAGE TEMPERATURE: –20° to 70°C.
HUMIDITY: <80% @ 35°C non-condensing.
DISPLAY TYPE: 2-line × 16 character VFD.
DIMENSIONS: 89mm high × 213mm wide × 411mm deep (3½ in × 8
of either connector.
8- position quick disconnect terminal block for output (4), sense (2), and DVM (2).
<0.8V.
(0.1 × specification)/°C.
1.888.KEITHLEY
w w w.keithley.com
GENERAL
(U.S. only)
Dual-Channel Battery/Charger
Simulator with External Triggering
3
8
in × 16
3
16
in).
A
NOTES
1. PLC = 1.00.
2. Following 15 minute warm-up, the change in output over 8 hours under ambient temperature, constant load,
3. Remote sense, at output terminals, 0.5A to 5A typical.
4. Remote sense, with 4.5m (15 ft) of 16 gauge (1.31mm
5. Minimum current in constant current mode is 6mA.
6. 60Hz (50Hz).
7. PLC = Power Line Cycle. 1PLC = 16.7ms for 60Hz operation, 20ms for 50Hz operation.
8. Display off.
9. Speed includes measurement and binary data transfer out of GPIB.
10. Typical values, peak-to-peak noise equals 6 times rms noise.
11. Based on settled signal: 100µs pulse trigger delay.
12. Also applies to other apertures that are integer multiples of 1PLC.
13. Recovery to within 20mV of previous level.
G R E A T E R
and line operating conditions.
test environment, 1.5A load change (0.15A to 1.65A).
M E A S U R E
O F
C O N F I D E N C E
2
) wire and 1W resistance in each lead to simulate typical

Related parts for 2306-VS