2306 KEITHLEY, 2306 Datasheet - Page 5

58T8423

2306

Manufacturer Part Number
2306
Description
58T8423
Manufacturer
KEITHLEY
Datasheets

Specifications of 2306

No. Of Outputs
2
Output Voltage
15V
Output Voltage 2
15V
Output Current
5A
Output Current 2
5A
Load Regulation
0.01%
Length
411mm
Width
213mm
Height
89mm
Weight
3.2kg
Power Supply Output Type
Variable
Input Voltage
100VAC To 120VAC / 220VAC To 240VAC
Power Rating
50W

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
2306019201W
Manufacturer:
AGILENT
Quantity:
336
Part Number:
23061-1V
Manufacturer:
HRS
Quantity:
2 000
Part Number:
230619121242
Manufacturer:
VISHAY/威世
Quantity:
20 000
Part Number:
230619121302
Manufacturer:
VISHAY/威世
Quantity:
20 000
Part Number:
230619124752
Manufacturer:
VISHAY/威世
Quantity:
20 000
Part Number:
230622
Manufacturer:
BSI
Quantity:
30 000
Part Number:
230625-3997-02
Quantity:
4 943
Part Number:
2306566
Manufacturer:
Phoenix Contact
Quantity:
275
Part Number:
2306B
Manufacturer:
ST
0
2302
2306, 2306-PJ
Output #1 (Battery)
DC VOLTAGE OUTPUT (2 Years, 23°C ± 5°C)
OUTPUT VOLTAGE: 0 to +15V DC.
OUTPUT ACCURACY: ±(0.05% + 3mV).
PROGRAMMING RESOLUTION: 1mV.
READBACK ACCURACY
READBACK RESOLUTION: 1mV.
OUTPUT VOLTAGE SETTLING TIME: 5ms to within stated accuracy.
LOAD REGULATION: 0.01% + 2mV.
LINE REGULATION: 0.5mV.
STABILITY
MEASUREMENT TIME CHOICES: 0.01 to 10PLC
AVERAGE READINGS: 1 to 10.
READING TIME
TRANSIENT RESPONSE:
REMOTE SENSE: 1V max. drop in each lead. Add 2mV to the voltage load regulation specification for
VARIABLE OUTPUT IMPEDANCE
RANGE: 0 to 1.00W in 0.01W steps. Value can be changed with output on.
DC CURRENT (2 Years, 23°C ± 5°C)
OUTPUT CURRENT (2302):
CONTINUOUS AVERAGE OUTPUT CURRENT (2306, 2306-PJ):
CONTINUOUS AVERAGE SINK CURRENT:
SOURCE COMPLIANCE ACCURACY: ±(0.16% + 5mA)
PROGRAMMED SOURCE COMPLIANCE RESOLUTION: 1.25mA.
READBACK ACCURACY
READBACK RESOLUTION: 5A Range:
LOAD REGULATION: 0.01% + 1mA.
LINE REGULATION: 0.5mA.
STABILITY
MEASUREMENT TIME CHOICES: 0.01 to 10PLC
AVERAGE READINGS: 1 to 10.
READING TIME
Transient Recovery Time
Transient Voltage Drop
each 1V change in the negative output lead due to load current change. Remote sense required.
Integrity of connection continually monitored. If compromised, output will turn off automatically
once settable window (±0 to ±8V) around normal voltage exceeded.
0–4V: 5A max.
>4V: I
Channel #2 (Charger) OFF:
Channel #2 (Charger) ON:
Peak currents can be a maximum of 5A provided the average current is within the above limits.
Channel #2 (Charger) OFF:
Channel #2 (Charger) ON:
I = 50W/(V
I = (50W – Power consumed by channel #2)/(V
The power consumed by channel #2 is calculated as:
0–5V: 3A max.
5–15V: Derate 0.2A per volt above 5V. Compliance setting controls sinking.
Available current = (50W – Power consumed by channel #2)/5; 3A max. (0–5V).
Derate 0.2A per volt above 5V.
1.888.KEITHLEY
Channel #2 sourcing current:
Channel #2 sinking current:
MAX
w w w.keithley.com
Power consumed = (V
Power consumed = 5 × (sink current)
4
2
: 0.01% + 50µA.
: 0.01% + 0.5mV.
= 60W/(V
SET
1, 8, 9
1, 8, 9
channel 1 + 6V); 5A max.
: 31ms, typical.
: 31ms, typical.
OUT
1
:
1
+6) (not intended to be operated in parallel).
: ±(0.05% + 3mV).
5A Range:
5mA Range:
500mA Range: ±(0.2% + 20µA) (2306-PJ only).
5mA Range:
500mA Range: 10µA (2306-PJ only).
13
SET
channel 2 + 6V) × (current supplied)
High Bandwidth
<75mV
<40µs
±(0.2% + 200µA).
±(0.2% + 1µA) (2302 and 2306).
100µA.
0.1µA (2302 and 2306).
(U.S. only)
3
3
or <60µs
or <100mV
7
7
, in 0.01PLC steps.
, in 0.01PLC steps.
SET
5
channel 1 + 6V); 5A max.
.
4
4
<250mV
Battery Simulator
Battery/Charger Simulators
Low Bandwidth
<80µs
3
3
or <100µs
or <400mV
4
4
A
PULSE CURRENT MEASUREMENT OPERATION
TRIGGER LEVEL:
TRIGGER DELAY: 0 to 100ms, in 10µs steps.
INTERNAL TRIGGER DELAY: 15µs.
HIGH/LOW/AVERAGE MODE:
PULSE CURRENT MEASUREMENT ACCURACY
BURST MODE CURRENT MEASUREMENT
MEASUREMENT APERTURE: 33.3µs.
CONVERSION RATE: 3650/second, typical.
INTERNAL TRIGGER DELAY: 15µs.
NUMBER OF SAMPLES: 1 to 5000.
TRANSFER SAMPLES ACROSS IEEE BUS IN BINARY MODE: 4800 bytes/s, typical.
LONG INTEGRATION MODE CURRENT MEASUREMENT
2302, 2306: Available on 5A range only.
2306-PJ: Available on 5A and 500mA current ranges.
MEASUREMENT TIME
DIGITAL VOLTMETER INPUT (2 Years, 23°C ± 5°C)
INPUT VOLTAGE RANGE: –5 to +30V DC.
INPUT IMPEDANCE: 2MW typical.
MAXIMUM VOLTAGE (either input terminal) WITH RESPECT TO OUTPUT LOW: –5V, +30V.
READING ACCURACY
READING RESOLUTION: 1mV.
CONNECTOR: HI and LO input pair part of Output #1’s terminal block.
MEASUREMENT TIME CHOICES: 0.01 to 10PLC
AVERAGE READINGS: 1 to 10.
READING TIME
G R E A T E R
500 µs – <1 PLC
100 µs – 200 µs
200 µs – 500 µs
5A CURRENT RANGE
500mA CURRENT RANGE (2306-PJ)
Measurement Aperture Settings: 33.3µs to 833ms, in 33.3µs steps.
Average Readings: 1 to 100.
Aperture
<100 µs
1 PLC
>1 PLC
5A Range:
1A Range:
100mA Range: 0.1mA to 100mA, in 100µA steps.
500mA Range: 0.5mA to 500mA, in 0.5mA steps.
100mA Range: 0.1mA to 100mA, in 100µA steps.
10mA Range: 100µA to 10mA, in 100µA steps.
12
1, 8, 9
M E A S U R E
: 31ms, typical.
1
6
: ±(0.05% + 3mV).
5mA to 5A, in 5mA steps.
1mA to 1A, in 1mA steps.
: 850ms (840ms) to 60 seconds in 1ms steps.
0.2% + 900 µA + 2 mA
0.2% + 900 µA + 1.5 mA
0.2% + 900 µA + 1 mA
0.2% + 600 µA + 0.8 mA
0.2% + 400 µA + 0 mA
0.2% + 400 µA + 100 µA
5A Range
±(% reading + offset + rms noise
O F
C O N F I D E N C E
11
7
(2 Years, 23°C ±5°C):
, in 0.01PLC steps.
Accuracy
500mA Range (2306-PJ)
0.2% + 90 µA + 2 mA
0.2% + 90 µA + 1.5 mA
0.2% + 90 µA + 1 mA
0.2% + 60 µA + 0.8 mA
0.2% + 40 µA + 0 mA
0.2% + 40 µA + 100 µA
10
)

Related parts for 2306