M29W640FT70N6E Micron Technology Inc, M29W640FT70N6E Datasheet - Page 22

no-image

M29W640FT70N6E

Manufacturer Part Number
M29W640FT70N6E
Description
Manufacturer
Micron Technology Inc
Datasheet

Specifications of M29W640FT70N6E

Cell Type
NOR
Density
64Mb
Access Time (max)
70ns
Interface Type
Parallel
Boot Type
Top
Address Bus
23/22Bit
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
8M/4M
Supply Current
10mA
Mounting
Surface Mount
Pin Count
48
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W640FT70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W640FT70N6E
Manufacturer:
ST
Quantity:
17 280
Part Number:
M29W640FT70N6E
Manufacturer:
ST
0
Part Number:
M29W640FT70N6E
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
M29W640FT70N6E
Quantity:
5
4.1.10
22/71
Program command
The Program command can be used to program a value to one address in the memory
array at a time. The command requires four Bus Write operations, the final write operation
latches the address and data, and starts the Program/Erase Controller.
Programming can be suspended and then resumed by issuing a Program Suspend
command and a Program Resume command, respectively (see
Suspend command
If the address falls in a protected block then the Program command is ignored, the data
remains unchanged. The Status Register is never read and no error condition is given.
During the program operation the memory will ignore all commands. It is not possible to
issue any command to abort or pause the operation. Typical program times are given in
Table 8: Program, Erase times and Program, Erase Endurance
operations during the program operation will output the Status Register on the Data
Inputs/Outputs. See the section on the Status Register for more details.
After the program operation has completed the memory will return to the Read mode, unless
an error has occurred. When an error occurs the memory will continue to output the Status
Register. A Read/Reset command must be issued to reset the error condition and return to
Read mode.
Note that the Program command cannot change a bit set at ’0’ back to ’1’. One of the Erase
Commands must be used to set all the bits in a block or in the whole memory from ’0’ to ’1’.
and
Section 4.1.9: Program Resume
command).
cycles. Bus Read
Section 4.1.8: Program

Related parts for M29W640FT70N6E