166981-005 FCI, 166981-005 Datasheet - Page 4

no-image

166981-005

Manufacturer Part Number
166981-005
Description
Manufacturer
FCI
Datasheet

Specifications of 166981-005

Lead Free Status / Rohs Status
Not Compliant
1.0
2.0
3.0
TITLE
Specification of Requirements for Cable Preparation, Wire Termination and
Copyright FCI
Form E-3334
Rev E
PURPOSE
This specification covers end product and workmanship requirements for cable preparation, wire termination and
assembly of the following Metral™ connectors using the 72392 type insulation displacement contacts.
SCOPE
GENERAL
3.1
3.2
3.3
3.4
Assembly of Connectors Using 72392-type Contacts
72476-type 4x6 Metral™ unshielded cable connectors
72477-type 4x12 Metral™ unshielded cable connectors
88940-type 2x6 & 2x10 Metral™ unshielded cable connectors
Recommended cable preparation
Recommendations on wire types that may be terminated.
No deviation of wire size, insulation type or insulation thickness from those listed in section
“Recommended Wire Sizes and Insulations” should be used without approval of the FCI engineering
design group responsible for this product. Please refer all question to your local FCI representative.
Recommended requirements on completed termination
Recommended repair procedures for wire terminations
Assembly of components after wire termination
Method of Specifying
The cable assembly and detail drawings should reference this specification when applicable. All
exceptions to the requirements of this specification should be clearly described in the notes of the cable
assembly drawing. We do not recommend any exceptions unless approval is obtained in advance from
the FCI engineering design group.
Workmanship
Workmanship shall be of a level that indicates controlled conditions of manufacture such that subsequent
operations, functionality and performance are not degraded.
Usage
The connectors covered by this instruction are intended for use in a wide variety of environments and are
designed to meet the conditions specified in Bellcore GR-1217-CORE and IEC-61076-4-110.
All product where the part number ends in ‘LF’ meet the European Union directives and other country
regulations as described in GS-22-008. The part numbers that do not end in ‘LF’ meet all regulations
except for Pb in SnPb plating.
All products covered by this specification will not withstand exposure to convection, infra-red or vapor
phase reflow ovens. Do not heat this product above 110°C.
Visual
Visual examinations shall be performed with a magnification of up to 10x. (8 to 10x recommended)
TYPE
APPLICATION SPECIFICATION
Banned/Restricted Substances
Manufacturing Processability
PDM: Rev:J
NUMBER
PAGE
AUTHORIZED BY
STATUS
STATUS:
J.R. Volstorf
4 of 29
UNRESTRICTED
Released
GS-20-002
REVISION
DATE
25-Apr-06
Printed: Nov 27, 2010
J
GS-01-001
.