Specification of Requirements for Cable Preparation, Wire Termination and
Copyright FCI
Form E-3334
Rev E
8.2
ACCEPTABLE WIRE TERMINATION
Assembly of Connectors Using 72392-type Contacts
88940 - type Metral™ Unshielded Connectors
These connectors have only a wire strain relief on each contact and do not have a cable jacket strain
relief option. Therefore there is no requirement on the position of the cable jacket to the connector.
Multiple connectors may be attached to the same cable.
Caution: The wire strain relief of each contact must be
closed by the wire insertion punch even if no wire is
inserted into the contact! If the strain reliefs are not
closed, a short can occur between contacts on both
shielded and unshielded connectors or between the
contact and metal shields on shielded connectors
The automatic wire terminators will set all the unused contacts unless the machine cycle
is interrupted. When using hand tools, the operator must index the connector sub-
assembly to all unused positions and activate the hand tool.
Figure 8 Dimensions - Multiple Unshielded Connectors per Cable