74LVCV2G66GD,125 NXP Semiconductors, 74LVCV2G66GD,125 Datasheet - Page 4

IC SWITCH DUAL SPST 8XSON

74LVCV2G66GD,125

Manufacturer Part Number
74LVCV2G66GD,125
Description
IC SWITCH DUAL SPST 8XSON
Manufacturer
NXP Semiconductors
Type
Analog Switchr
Datasheet

Specifications of 74LVCV2G66GD,125

Package / Case
8-XSON
Function
Switch
Circuit
2 x SPST - NO
On-state Resistance
7.3 Ohm
Voltage Supply Source
Single Supply
Voltage - Supply, Single/dual (±)
2.3 V ~ 5.5 V
Current - Supply
0.1µA
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
On Resistance (max)
13 Ohms
On Time (max)
4.7 ns
Off Time (max)
7.9 ns
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.3 V
Maximum Power Dissipation
250 mW
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Propagation Delay Time
0.2 ns, 0.3 ns, 0.4 ns
Switch Current (typ)
0.0001 mA
Package
8XSON8U
Maximum On Resistance
30@2.7V Ohm
Maximum Propagation Delay Bus To Bus
0.2(Typ)@5.5V|0.3(Typ)@3.6V|0.4(Typ)@2.7V ns
Maximum Low Level Output Current
50 mA
Maximum Turn-off Time
7.9(Typ)@2.7V ns
Maximum Turn-on Time
4.7(Typ)@2.7V ns
Switch Architecture
SPST
Power Supply Type
Single
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
74LVCV2G66GD-G
74LVCV2G66GD-G
935286865125

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
74LVCV2G66GD,125
Manufacturer:
Vishay
Quantity:
3 298
NXP Semiconductors
8. Limiting values
Table 5:
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
[1]
[2]
9. Recommended operating conditions
Table 6:
[1]
[2]
74LVCV2G66
Product data sheet
Symbol
V
V
I
I
V
I
I
I
T
P
Symbol
V
V
V
T
Δt/ΔV
IK
SK
SW
CC
GND
stg
amb
CC
I
SW
tot
CC
I
SW
The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
For TSSOP8 package: above 55 °C the value of P
For VSSOP8 package: above 110 °C the value of P
For XSON8U package: above 118 °C the value of P
To avoid sinking GND current from terminal nZ when switch current flows in terminal nY, the voltage drop across the bidirectional switch
must not exceed 0.4 V. If the switch current flows into terminal nZ, no GND current will flow from terminal nY. In this case, there is no
limit for the voltage drop across the switch.
Applies to control signal levels.
Limiting values
Recommended operating conditions
Parameter
supply voltage
input voltage
switch voltage
ambient temperature
input transition rise and fall rate
Parameter
supply voltage
input voltage
input clamping current
switch clamping current
switch voltage
switch current
supply current
ground current
storage temperature
total power dissipation
All information provided in this document is subject to legal disclaimers.
Conditions
enable and disable mode
V
V
CC
CC
tot
Conditions
V
V
enable and disable mode
V
T
tot
tot
I
I
SW
amb
derates linearly with 2.5 mW/K.
= 2.3 V to 2.7 V
= 2.7 V to 5.5 V
Rev. 3 — 16 June 2010
< −0.5 V or V
< −0.5 V or V
derates linearly with 8 mW/K.
derates linearly with 7.8 mW/K.
> −0.5 V or V
= −40 °C to +125 °C
I
I
> 6.5 V
> 6.5 V
SW
< 6.5 V
[1]
[2]
[2]
Overvoltage tolerant bilateral switch
Min
2.3
0
0
−40
-
-
[1]
[2]
Min
−0.5
−0.5
−50
-
−0.5
-
-
−100
−65
-
Typ
-
-
-
-
-
-
74LVCV2G66
Max
+6.5
+6.5
-
±50
+6.5
±50
100
-
+150
250
Max
5.5
5.5
5.5
+125
20
10
© NXP B.V. 2010. All rights reserved.
Unit
V
V
V
°C
ns/V
ns/V
Unit
V
V
mA
mA
V
mA
mA
mA
°C
mW
4 of 23

Related parts for 74LVCV2G66GD,125