FQM1-MMA21 Motion Control Modules with Analog I/O
336
System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations
A550
A552
A559
A560
A561
Address
00 to 15 Analog Input PV
00
01 to 06
07
08
09
10 to 14
15
01 to 15 Number of Analog
00 to 15 Analog Output 1
00 to 15 Analog Output 2
Bits
Analog Input Sta-
tus
Samples
Output Value
Output Value
Name
Contains the value input from the analog input port (using either the END
refresh or immediate refresh) in 4-digit hexadecimal.
The PV range depends on the input range:
• 0 to 10 V:
• 0 to 5 V or 1 to 5 V:
• − 10 to 10 V:
User Adjustment Com-
pleted
Reserved
Analog Sampling Started OFF: Not started
Factory Adjustment Data
Error
User Adjustment Data
Error
Reserved
Analog Sampling Overlap OFF: Normal sampling
Indicates the number of data samples actually input since sampling started.
When an END refresh is selected, the 4-digit hexadecimal value set here by the
user is output from analog output port 1.
When immediate refreshing is selected, the 4-digit hexadecimal value being out-
put from analog output port 1 is stored here for monitoring. The output value
range depends on the output range, as shown below.
• 0 to 10 V, 0 to 5 V or 1 to 5 V: FF38 to 1068 hex
• − 10 to 10 V: EA84 to 157C hex
Note
1. Set the analog output method (END or immediate refreshing) with the System
2. Specify the output range with the output 1 setting.
This word has the same settings as the analog output 1 output value (A560),
above. (When an END refresh is selected, set the value to output from analog
output port 2. When an immediate refresh is selected, the output value is stored
here for monitoring.)
Note
1. Set the analog output method (END or immediate refresh) with the System
2. Specify the output range with the output 2 setting.
Setup’s output method setting. A setting of 0 hex specifies an END refresh.
This setting applies to both analog output 1 and 2.
Setup’s output method setting. A setting of 0 hex specifies an END refresh.
This setting applies to both analog output 1 and 2.
FE70 to 20D0 hex
FF38 to 1068 hex
DDA0 to 2260 hex
OFF: Not adjusted
ON: Adjustment completed
ON: Started
OFF: No Error
ON: Error (Checked at power ON.)
OFF: No Error
ON: Error (Checked at power ON.)
ON: The next sampling operation occurred before
the present sampling operation completed.
Function
Appendix C
Module
With immedi-
ate refresh:
Module
With END
refresh: User
Controlled