XW2Z-200J-B10 Omron, XW2Z-200J-B10 Datasheet - Page 174

no-image

XW2Z-200J-B10

Manufacturer Part Number
XW2Z-200J-B10
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B10

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB10
Pulse Inputs
Minimum response pulse
At 50 kHz
At 500 kHz Operation may not be reliable above 50 kHz.
Item
Phase A
Phase B
Encoder Inputs A and B
Encoder Input Z or Sensor Input
Waveform of Encoder Inputs A and B
Signal rise and fall must be 3 µs max.
50-kHz pulse with 50% duty ratio
Relationship to Phase Differential Inputs A and B
T1, T2, T3,and T4 must be 4.5 µs min.
There must be 4.5 µs min. between phase-A and
phase-B change points.
50%
Encoder Input Z Waveform
The pulse width must be 90 µs min.
ON
50%
OFF
ON
OFF
ON
OFF
ON
50%
OFF
3 µs max.
T1
90 µs min.
10 µ s min.
T2
20 µs min.
20 µs min.
3 µs max.
T3
10 µ s min.
T4
Specification
Encoder Inputs A and B
Encoder Input Z or Sensor Input
Phase A
Phase B
Encoder Inputs A and B
Encoder Input Z or Sensor Input
Encoder Inputs A and B Waveform
Square waveform
1-MHz pulse with 50% duty ratio
Relationship with Phase Differential Inputs A and B
T1, T2, T3,and T4 must be 0.5 µs min.
There must be 0.5 µs min. between phase-A and
phase-B change points.
Encoder Input Z Waveform
The pulse width must be 10 µs min.
Encoder Inputs A and B Waveform
Square waveform
50-kHz pulse with 50% duty ratio
Relationship to Phase Differential Inputs A and B
T1, T2, T3,and T4 must be 4.5 µs min.
There must be 4.5 µs min. between phase-A and
phase-B change points.
Encoder Input Z Waveform
The pulse width must be 90 µs min.
ON
50%
OFF
ON
50%
OFF
ON
OFF
ON
50%
OFF
ON
50%
OFF
ON
50%
OFF
OFF
ON
50%
OFF
ON
90 µs min.
T1
T1
10 µs min.
0.5 µs min.
10 µ s min.
T2
T2
20 µs min.
2 µs min.
20 µs min.
1 µs min.
T3
T3
10 µ s min.
0.5 µs min.
Section 7-5
T4
T4
151