5-7-3
Automatic Backup to
Flash Memory
Operation Settings at Startup and Maintenance Functions
Flash Memory
1,2,3...
Note
1. Register a password either online or offline.
2. Set password protection online.
The user program and parameters are automatically backed up in flash mem-
ory whenever they are written.
The backup status will be displayed in a Memory Backup Status Window by
the CX-Programmer when backing up data from the CX-Programmer for
transfer operations other than normal data transfers (PLC/Transfer). To
obtain this window, display of the backup status dialog box must be selected
• The following data is backed up automatically: User program, parameters
• The automatic backup is executed whenever the Module user program or
• The user program and parameter data written to flash memory is auto-
a. Select the Module in the Device Type drop-down menu and select
b. Select Protection from the PLC Properties Dialog Box and input the
a. Select PLC/Protection/Set. The Protection Setting Dialog Box will be
b. Click the OK Button.
(including the System Setup, absolute offset data, and analog I/O offset
gain adjustment values), and some DM Area data (only for the Coordina-
tor Module).
parameter area is written (e.g., for data transfer operations from the CX-
Programmer and online editing).
matically transferred to user memory at startup.
Properties from the View Menu.
password.
displayed.
Automatic backup
User memory
Flash memory
Module
Automatically restored when Module is turned ON.
User program
Parameters
Data transfer from
CX-Programmer
Transfer operation
Online editing from
CX-Programmer
Section 5-7
119