6.2
The following U-transceiver registers are reset upon the transition to state ’Deactivated’:
Register
U-Interface Registers
TEST
LOOP
FEBE
NEBE
BERC
6.3
The point of time when mode settings are detected and executed differs with the mode
register type. Two different behaviors can be classified
• evaluation and execution after SW-reset (C/I= RES, RES1) or upon transition out of
• immediate evaluation and execution
Below the mode registers are listed and grouped according to the different evaluation
times as stated above.
Register
Registers Evaluated After SW-Reset or Upon Transition Out of State Deactivated
MFILT
Immediate Evaluation and Execution
OPMODE
M4RMASK
M4WMASK
TEST
LOOP
Data Sheet
state ’Deactivated’
Note: Write access to these registers/bits is allowed only, while the state machine is
in state Reset or Deactivated.
Reset of U-Transceiver Functions in State ’Deactivated’
Mode Register Evaluation Timing
complete register
Reset to
00
00
0000
Affected Bits
complete register
bit FEBE
complete register
complete register
complete register
H
H
H
only the bits BER and CCRC are reset
Affected Bits/ Comment
only the bits LBBD, LB2 and LB1 are reset
reset upon deactivation
reset upon deactivation
reset upon deactivation
120