HS9Z-A61 IDEC Corporation, HS9Z-A61 Datasheet - Page 15

no-image

HS9Z-A61

Manufacturer Part Number
HS9Z-A61
Description
Straight Key for Idec HS6B Safety Switch
Manufacturer
IDEC Corporation
Datasheet

Specifications of HS9Z-A61

Lead Free Status / Rohs Status
RoHS Compliant part
400
Actuator Angle Adjustment
Minimum Radius of Hinged Door
When using the HS9Z-A52 Actuator
When using the HS9Z-A55 Angle Adjustable Actuator
Use a cable gland with a degree of protection IP67
When Using Flexible Conduits (Example)
Flexible conduit example: VF-03 (Nihon Flex)
Conduit Port Size
G1/2
PG13.5
M20
Using the screw (M3 hex socket head screw), the actuator angle can be
adjusted (refer to the dimensional drawing). Adjustable angle: (0˚) to 20˚
The larger the adjusted angle of the actuator, the smaller the applicable
radius of the door opening.
When using the interlock switch on hinged doors, refer to the minimum radius
of doors shown below. When using on doors with small minimum radius, use
the angle adjustable actuator (HS9Z-A55).
Note: Because deviation or dislocation of hinged doors may occur in actual applications, make sure
of the correct operation before installation.
When the door hinge is on the extension line of the interlock switch surface:
When door hinge is on the extension line of the actuator mounting surface:
When door hinge is on the extension line of the interlock switch surface:
50 mm
When door hinge is on the extension line of the actuator mounting surface:
70 mm
Plastic Cable Gland
G1/2, PG13.5, M20
Precautions
Door Hinge
Door Hinge
9 max.
Metal Cable Gland
RLC-103 (Nihon Flex)
RBC-103PG13.5 (Nihon Flex)
RLC-103EC20 (Nihon Flex)
Door Hinge
Door Hinge
all dimensions in mm
Applicable Cable Glands
www.idec.com
When Using Multi-core Cables (Example)
Actuator Angle Adjustment for the HS9Z-A55
Conduit Port Size
G1/2
PG13.5
M20
Different cable glands are used depending on the cable sheath outside diameter. When
purchasing a cable gland, confi rm that the cable gland is applicable to the cable sheath
outside diameter.
When using a 1/2-14NPT cable gland, use the HS5B interlock switch with M20 conduit
port (Part No.: HS5B-***BM) together with an adapter (Part No.: MA-M/NPT 20X1.5
5402-0110, K-MECS) and a gasket (Part No.: GP M20, K-MECS). Install a gasket between
the interlock switch and the adapter. Apply sealing tape between the cable gland and
the adapter to make sure of IP67 protection for the enclosure.
After installing the actuator, open the door. Then adjust the actuator so that
its edge can be inserted properly into the entry slot of the safety switch.
Recommended tightening torque: 0.8 N-m (approx. 8.0 kgf-cm)
After adjusting the actuator angle, apply loctite or the like to the adjustment
screw so as to prevent its loosening.
Using the angle adjustment screw, the actuator angle can be adjusted (see
fi gures on page 370. Adjustable angle: 0 to 20°
The larger the adjusted angle of the actuator, the smaller the applicable
radius of the door opening.
After installing the actuator, open the door. Then adjust the actuator so that
its edge can be inserted properly into the actuator entry slot of the interlock
switch.
After adjusting the actuator angle, apply Loctite to the adjustment screw so
that the screw will not loosen.
Horizontal Swing
Vertical Swing
Door Hinge
Door Hinge
Plastic Cable Gland
SCS-10*
(Seiwa Electric)
ST13.5
(K-MECS)
ST-M20X1.5
(K-MECS)
Door Interlock Switches
Metal Cable Gland
ALS-16**
(Nihon Flex)
ABS-**PG13.5
(Nihon Flex)
ALS-**EC20
(Nihon Flex)
Door Hinge
Door Hinge

Related parts for HS9Z-A61