HS9Z-A61 IDEC Corporation, HS9Z-A61 Datasheet - Page 12

no-image

HS9Z-A61

Manufacturer Part Number
HS9Z-A61
Description
Straight Key for Idec HS6B Safety Switch
Manufacturer
IDEC Corporation
Datasheet

Specifications of HS9Z-A61

Lead Free Status / Rohs Status
RoHS Compliant part
Door Interlock Switches
For Rotating Head Directions
Wire Connection
In order to avoid electric shock or a fi re, turn the power off before installation,
removal, wire connection, maintenance, or inspection of the switch.
If relays are used in the circuit between the safety switch and the load,
consider degrees of the danger and use safety relays, since welded or sticking
contacts of standard relays may invalidate the functions of the safety switch.
Regardless of door types, do not use the safety switch as a door stop. Install
a mechanical door stop at the end of the door to protect the safety switch
against excessive force.
Do not apply excessive shock to the switch when opening or closing the door.
A shock to the door exceeding 1,000 m/sec
contacts of the switch to chatter, and a malfunction of the switch may occur.
For connection of wires, unscrew the cover. Unnecessary loosening of other
screws may cause a malfunction of the switch.
The heads of the HS5E/HS5B can be rotated in 90° increments after removing
the 4 screws on the corners of the head. Prevent entry of foreign objects into
the switch during removal of the head. Tighten these screws with torque
designated in the instruction sheet. Improper torque may cause errors.
When using the interlock switch on hinged doors, refer to the minimum radius
of doors shown below. When using on doors with small minimum radius, use
the angle adjustable actuator (HS9Z-A55).
The HS2B has 3 conduit ports, which are closed as a part of the molded
switch housing.
Make an opening for wire connection by breaking one of the conduit-port
knockouts on the switch housing using a screwdriver.
When breaking the conduit port, take care not to damage the contact block or
other parts inside the switch.
Factory Setting
Minimum Radius of Hinged Doors
Head can be rotated.
2
(approx. 100G) may cause the
USA: 800-262-IDEC
Operation Precautions - for all series
Safety Precautions
HS5E/HS5B Precautions
HS2B Precautions
Canada: 888-317-IDEC
Note:
applications, make sure of the correct operation before installation.
When using the HS9Z-A52 Actuator
Do not place a PLC in the circuit between the safety switch and the load. The
safety security can be endangered in the event of a malfunction of the PLC.
Do not disassemble or modify the switch. It may cause a breakdown or an
accident.
Prevent foreign objects such as dust and liquids from entering the switch
while connecting conduit or wiring.
If the operating atmosphere is contaminated, use a protective cover to
prevent the entry of foreign objects into the switch through the actuator entry
slots.
Entry of a considerable amount of foreign objects into the switch may affect
the mechanism of the switch and cause a breakdown.
Do not store the switches in a dusty, humid, or organic-gas atmosphere.
When the door hinge is on the extension line of the interlock switch surface:
When door hinge is on the extension line of the actuator mounting surface:
Cracks or burrs on the conduit entry may deteriorate the housing protection
against water.
When changing to another conduit port, close the unused opening with an
optional plug (Part No. HS9Z-P1).
Because deviation or dislocation of hinged doors may occur in actual
Door Hinge
Door Hinge
Door Hinge
Door Hinge
Precautions
397