AT-FM-10K BANNER ENGINEERING, AT-FM-10K Datasheet - Page 8

no-image

AT-FM-10K

Manufacturer Part Number
AT-FM-10K
Description
Control Module, Two Hand; Solid State (NPN, PNP), Relay (Auxiliary N.C.); 200 W
Manufacturer
BANNER ENGINEERING
Type
Safetyr
Datasheets

Specifications of AT-FM-10K

Brand/series
Duo-Touch
Contact Form
SPDT-NO/NC
Dimensions
22.5mmW×84mmH×118mmD
Enclosure Rating
IP20
Indicator
4 Green LED, 1 Red LED
Ip Rating
IP20
Material, Casing
Polycarbonate
Mounting
DIN Rail
Mounting Type
DIN Rail
Number Of Outputs
4
Output Type
Digital/Relay
Power Consumption
200 W
Primary Type
Controller
Standards
cULus, cCSAus, CE
Temperature, Operating
0 to +50 °C
Voltage, Supply
24 VDC
Coil Voltage Vac Nom
24V
Coil Voltage Vdc Nom
24V
Contact Current Max
6A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
24V
Contact Configuration
SPST-NO
No. Of Poles
1
Lead Free Status / Rohs Status
RoHS Exempt Product
For Use With
Two-Hand Control
L1/+V dc
Figure 4. Connection to two STB Touch Buttons with contact
outputs
L1/+V dc
Figure 6. Connection to two mechanical push buttons with
contact outputs
8
+ –
STB2
SW1
Machine
Control
Machine
Circuit
Control
Circuit
If power is applied to the Safety Module before power is applied to the electronic hand controls, an output from the Safety
Module could result and may trigger machine motion. Also, electronic hand controls cannot guarantee the state of their out-
puts at the time power is applied to them.
WARNING: . . . Interfacing Safety Outputs
NEVER wire or interface an intermediate device (e.g., PLC, PES, PC) that can fail in such a manner that there is a
loss of the safety stop command to the MPCEs.
To do so could result in serious bodily injury or death.
24V ac/dc
24V ac/dc
+ –
SW2
STB1
* Arc Suppressor – See Warning
(1) See Warning about Interfacing Safety Outputs
Yellow
Yellow
Brown
White
White
Black
Black
A1
S12
S11
S13
S22
S21
S23
13
23
AT-FM-10K
K1
A1
S12
S11
S13
S22
S21
S23
13
23
AT-FM-10K
K1
K2
A2
Y1
Y2
14
24
K2
A2
Y1
Y2
14
24
Blue
(1)
www.bannerengineering.com - tel: 763-544-3164
MPCE2 MPCE1
MPCE
(1)
2
0V ac/dc
MPCE2 MPCE1
MPCE
MPCE
*
2
0V ac/dc
1
*
MPCE
*
L2/–V dc
1
*
L2/–V dc
L1/+V dc
Figure 5. Connection to two STB Touch Buttons with PNP
(sourcing) outputs
+ –
STB2
Logic
Machine
Control
Circuit
WARNING: . . . Wiring of Arc Suppressors
If arc suppressors are used, they MUST be in-
stalled as shown across the actuator coil of the
stop control elements (MSCs or MPCEs). NEVER
install suppressors directly across the output
contacts of the Safety Device or Module. It is
possible for suppressors to fail as a short circuit. If
installed directly across the output contacts, a
short-circuited suppressor will create an unsafe
condition which could result in serious injury or
death.
24V dc
+ –
STB1
Logic
Brown
White
White
Black
Black
AT-FM-10K Two-Hand Control Module
A1
AT-FM-10K
S12
S11
S13
S22
S21
S23
13
23
K1
K2
A2
Y1
Y2
14
24
Blue
(1)
MPCE2
MPCE
2
0V dc
MPCE
*
P/N 64137 F
MPCE1
1
*
L2/–V dc

Related parts for AT-FM-10K