AT-FM-10K BANNER ENGINEERING, AT-FM-10K Datasheet - Page 10

no-image

AT-FM-10K

Manufacturer Part Number
AT-FM-10K
Description
Control Module, Two Hand; Solid State (NPN, PNP), Relay (Auxiliary N.C.); 200 W
Manufacturer
BANNER ENGINEERING
Type
Safetyr
Datasheets

Specifications of AT-FM-10K

Brand/series
Duo-Touch
Contact Form
SPDT-NO/NC
Dimensions
22.5mmW×84mmH×118mmD
Enclosure Rating
IP20
Indicator
4 Green LED, 1 Red LED
Ip Rating
IP20
Material, Casing
Polycarbonate
Mounting
DIN Rail
Mounting Type
DIN Rail
Number Of Outputs
4
Output Type
Digital/Relay
Power Consumption
200 W
Primary Type
Controller
Standards
cULus, cCSAus, CE
Temperature, Operating
0 to +50 °C
Voltage, Supply
24 VDC
Coil Voltage Vac Nom
24V
Coil Voltage Vdc Nom
24V
Contact Current Max
6A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
24V
Contact Configuration
SPST-NO
No. Of Poles
1
Lead Free Status / Rohs Status
RoHS Exempt Product
For Use With
Two-Hand Control
When switching inductive ac loads, it is good practice to protect the Safety Module outputs by installing appropriately-sized arc suppres-
sors. However, if arc suppressors are used, they must be installed across the load being switched (e. g., across the coils of external
safety relays), and never across the Safety Module’s output contacts (see WARNING, Arc Suppressors).
To perform the initial checkout, it is necessary to view the red Fault LED and the four green status indicators: Power, Input 1,
Input 2 and Output. Proceed with caution around open wiring.
If the Safety Module passes all of these tests, reconnect the output wires at terminals 13/14 and 23/24. Do not attempt to use the
Safety Module until all of the tests are passed.
To be Performed at every Power-up, Shift Change, and Tooling/Machine Setup Change
The daily checkout must be performed by a Designated Person, appointed and identified in writing by the employer, or by a
Qualified Person (see below).
10
1. Verify that the two actuating devices are properly connected to the Module.
2. Apply power to the Safety Module and to the actuating devices, if applicable.
3. Verify that only the Power indicator is ON. If any of the other Safety Module indicators are ON, disconnect the power to the Safety
4. Activate both hand controls simultaneously (within 0.5 seconds), and hold them engaged. Input 1 and Input 2 indicators should
5. Again, activate the two hand controls simultaneously, and hold them engaged. Input 1, Input 2, and Output indicators should come
6. Activate only one hand control and hold it engaged. Input 1 (Input 2) indicator should come ON. After more than 1/2 second, acti-
7. Remove power from the Safety Module and disconnect the monitor contact feedback loop at terminals Y1 and/or Y2. Re-apply
1. Verify that all point-of-operation guards are in place and operating properly.
Module and check all wiring. Do not continue this checkout procedure until the cause of the problem is corrected.
come ON. Release both hand controls simultaneously. Output indicator should go OFF.
ON. Release one hand control, while holding the other engaged. One of the indicators should remain ON. The Output indicator
should go OFF. Re-activate the hand control which was just released. The Output indicator should remain OFF. Release both hand
controls. Input 1 and Input 2 indicators should then be OFF.
vate the second hand control. Input 1 and 2 indicators should remain ON, while Output indicator remains OFF.
power to the Safety Module. Activate both hand controls simultaneously. Output indicator LED should remain OFF.
CAUTION: . . . Disconnect Power Prior to Checkout
Before performing the initial checkout procedure, make certain all power is disconnected from the machine to be
controlled.
Dangerous voltages may be present along the Safety Module wiring barriers whenever power to the machine control ele-
ments is ON. Exercise extreme caution whenever machine control power is or may be present. Always disconnect
power to the machine control elements before opening the enclosure housing of the Safety Module.
WARNING: . . . Do Not Use System Until Checkouts Are Verified
If all of the described checks cannot be verified, do not attempt to use the two-hand control safety system until the
defect or problem has been corrected. Attempts to use the guarded machine under such conditions could result in
serious bodily injury or death.
WARNING: . . . Do Not Use System Until Checkouts Are Verified
If all of the described checks cannot be verified, do not attempt to use the two-hand control safety system until the
defect or problem has been corrected. Attempts to use the guarded machine under such conditions could result in
serious bodily injury or death.
www.bannerengineering.com - tel: 763-544-3164
Initial Checkout Procedure
Daily Checkout Procedure
AT-FM-10K Two-Hand Control Module