AT-FM-10K BANNER ENGINEERING, AT-FM-10K Datasheet - Page 11

no-image

AT-FM-10K

Manufacturer Part Number
AT-FM-10K
Description
Control Module, Two Hand; Solid State (NPN, PNP), Relay (Auxiliary N.C.); 200 W
Manufacturer
BANNER ENGINEERING
Type
Safetyr
Datasheets

Specifications of AT-FM-10K

Brand/series
Duo-Touch
Contact Form
SPDT-NO/NC
Dimensions
22.5mmW×84mmH×118mmD
Enclosure Rating
IP20
Indicator
4 Green LED, 1 Red LED
Ip Rating
IP20
Material, Casing
Polycarbonate
Mounting
DIN Rail
Mounting Type
DIN Rail
Number Of Outputs
4
Output Type
Digital/Relay
Power Consumption
200 W
Primary Type
Controller
Standards
cULus, cCSAus, CE
Temperature, Operating
0 to +50 °C
Voltage, Supply
24 VDC
Coil Voltage Vac Nom
24V
Coil Voltage Vdc Nom
24V
Contact Current Max
6A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
24V
Contact Configuration
SPST-NO
No. Of Poles
1
Lead Free Status / Rohs Status
RoHS Exempt Product
For Use With
Two-Hand Control
To be Performed at Six-Month Intervals
This semi-annual checkout must be performed by a Qualified Person (a person who, by possession of a recognized degree or
certificate of professional training, or who, by extensive knowledge, training, and experience, has successfully demonstrated
the ability to solve problems relating to the installation, maintenance and use of the Safety System). Keep a copy of the test
results on or near the machine.
NOTE: Do not attempt any repairs to the Safety Module. It contains no field-replaceable components. Return it to the factory for warranty
repair or replacement.
If it becomes necessary to return a Safety Module to the factory:
AT-FM-10K Two-Hand Control Module
P/N 64137 F
2. Verify that the two actuating devices must be simultaneously engaged to actuate the machine.
3. For single-cycle machines: Verify that maintained engagement of the two actuating devices results in only one machine cycle.
4. Verify that the distance from each actuating device to the closest hazard point is not less than the calculated safety distance.
1. Perform the daily checkout procedure.
2. Perform the initial checkout procedure.
3. Calculate the separation distance, and verify that the actuating devices are far enough away from the nearest hazard point. Relo-
4. Verify that the actuating devices are positioned to require the use of both hands for operation, and are protected from false or
5. Inspect the machine controls and the connections to the Safety Module to ensure that wiring is correct and that no modifications
1. Contact Banner Factory Application Engineering at the address or at
2. Pack the component carefully. Damage which occurs in return ship-
cate the actuating devices, if necessary.
inadvertent operation.
have been made which could adversely affect the System.
For part-revolution clutch machinery: Verify that release of either actuating device results in the immediate arrest of the ma-
chine motion.
the numbers listed in this document. They will attempt to troubleshoot
the system from your description of the problem. If they conclude that
a component is defective, they will issue an RMA (Return Merchan-
dise Authorization) number for your paperwork, and give you the
proper shipping address.
ping is not covered by warranty.
WARNING: . . . Do Not Use System Until Checkouts Are Verified
If all of the described checks cannot be verified, do not attempt to use the two-hand control safety system until the
defect or problem has been corrected. Attempts to use the guarded machine under such conditions could result in
serious bodily injury or death.
CAUTION: . . . Abuse of Module After Failure
If an internal fault has occurred and the Module will not reset, do not tap, strike, or otherwise attempt to correct the fault
by a physical impact to the housing. An internal relay may have failed in such a manner that its replacement is required.
If the Module is not immediately replaced or repaired, multiple simultaneous failures may accumulate such that the
safety function can not be guaranteed.
Semi-Annual Checkout Procedure
www.bannerengineering.com - tel: 763-544-3164
Repairs
Figure 7. To remove a terminal block, insert a small
screwdriver into the slot as shown; pry to loosen
11