AT-FM-10K BANNER ENGINEERING, AT-FM-10K Datasheet
AT-FM-10K
Specifications of AT-FM-10K
Related parts for AT-FM-10K
AT-FM-10K Summary of contents
Page 1
... IEC 61508 Functional Safety of Electrical/Electronic/Programmable Electronic Safety-Related Systems ISO 62061 Functional Safety of Safety-Related Electrical, Electronic and Programmable Control Systems P/N 64137 F AT-FM-10K Two-Hand Control Module DUO-TOUCH® SG, for use with two actuating devices • Diverse-redundant microcontrollers • Monitors two Banner STB Self-Checking Optical Touch Buttons, or two mechanical push buttons • ...
Page 2
... Document Center: http://www.document-center.com/home.cfm Banner Enginering Corp. herewith declares that AT-FM-10K Two-Hand Control Module for industrial control is in conformity with the provisions of the Machinery Directive (Directive 98/37/EEC), and all essential Health and Safety Requirements have been met. Download the complete EC Declaration of Conformity as a PDF file at A DUO-TOUCH SG Two-Hand Control Safety Module (the “ ...
Page 3
... AT-FM-10K Two-Hand Control Module The Duo-Touch SG® Two-Hand Control Kit system complies with: • Two-hand control and Control Reliability requirements per OSHA 29CFR1910.217, ANSI NFPA 79, ANSI B11.19, and ANSI/RIA R15.06, • Type IIIC requirements of ISO 13851 (EN 574) Safety of Machinery – Two-Hand Control Devices, and • ...
Page 4
... This may result in exposure to a hazard. 4 Power Feedback Loop* SW1 SW2 Output < 0.5 s < 0.5 s > 0.5 s Figure 2. Model AT-FM-10K timing logic Mechanical Installation www.bannerengineering.com - tel: 763-544-3164 AT-FM-10K Two-Hand Control Module Feedback Open SW1 tied down SW2 tied down P/N 64137 F ...
Page 5
... AT-FM-10K Two-Hand Control Module CAUTION Install Hand Controls to Prevent Accidental Actuation Total protection for the two-hand control system from “defeat” is not possible. However, the user is required by OSHA reg- ulations to arrange and protect hand controls to minimize possibility of defeat or accidental actuation. Each actuating device requires a normally open and a normally closed (e.g., Form C or SPDT) hard contact, each capable of reliably conducting 24V dc (nominal) ...
Page 6
... C = the added distance due to depth penetration factor: 250 mm, per ISO 13855. The ISO 13855 “C” factor can be reduced the risk of encroachment is eliminated, but the safety distance must always be 100 mm or greater. NOTES: 6 Formula for EU-Certified Installations The formula used to calculate the minimum safety distance (S) from the nearest actuator to the danger zone is www.bannerengineering.com - tel: 763-544-3164 AT-FM-10K Two-Hand Control Module P/N 64137 F ...
Page 7
... If hand controls have metal housings, the housings must be connected to protective earth ground. If STB Touch Buttons with PNP outputs are used, the entire STB/AT-FM-10K system must be supplied with 24V dc. Electronic actuation devices, including STB Touch Buttons, must share the same voltage supply with the Safety Module. ...
Page 8
... MPCE2 MPCE1 Y2 short-circuited suppressor will create an unsafe L2/–V dc condition which could result in serious injury death. MPCE 14 1 MPCE www.bannerengineering.com - tel: 763-544-3164 AT-FM-10K Two-Hand Control Module STB1 Logic + – Blue Brown 24V AT-FM-10K White S12 Y1 S11 (1) Black ...
Page 9
... AT-FM-10K Two-Hand Control Module Connection to the Guarded Machine WARNING Interfacing MSCs NEVER wire an intermediate device(s) (e.g., PLC, PES, PC) between the Safety Module outputs and the Master Stop Control Element it switches in such a manner that in the event of a failure there is a loss of the safety stop com- mand such a manner that the safety function can be suspended, overridden, or defeated, unless accomplish- ed with the same or greater degree of safety ...
Page 10
... Attempts to use the guarded machine under such conditions could result in serious bodily injury or death. 1. Verify that all point-of-operation guards are in place and operating properly. 10 Initial Checkout Procedure Daily Checkout Procedure www.bannerengineering.com - tel: 763-544-3164 AT-FM-10K Two-Hand Control Module P/N 64137 F ...
Page 11
... AT-FM-10K Two-Hand Control Module 2. Verify that the two actuating devices must be simultaneously engaged to actuate the machine. 3. For single-cycle machines: Verify that maintained engagement of the two actuating devices results in only one machine cycle. For part-revolution clutch machinery: Verify that release of either actuating device results in the immediate arrest of the ma- chine motion ...
Page 12
... Minimum: Maximum: 15V ac/dc 250V ac / 24V dc resistive 30 mA ac/dc 0.45 W (0.45 VA) 15V ac/dc 250V ac / 24V dc resistive 30 mA ac/dc IEC 60947-5-1; AC15: 230V ac DC-13: 24V dc 0.45 W (0.45 VA) www.bannerengineering.com - tel: 763-544-3164 AT-FM-10K Two-Hand Control Module —— —— —— P/N 64137 F ...
Page 13
... AT-FM-10K Two-Hand Control Module Simultaneity Monitoring Period ≤ 500 milliseconds Status Indicators 4 green LED indicators: Power ON, Input 1 energized, Input 2 energized, Output 1 red LED indicator: Fault Construction Polycarbonate housing. Rated IEC IP20 Mounting Mounts to standard 35 mm DIN rail track. Safety Module must be installed inside an enclosure rated NEMA 3 (IEC IP54), or better ...
Page 14
... This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either AT-FM-10K Two-Hand Control Module www.bannerengin- brasil@banner- sensors@bannerengineering ...