DS21Q43AT Maxim Integrated Products, DS21Q43AT Datasheet - Page 15

IC FRAMER E1 QUAD 5V IND 128TQFP

DS21Q43AT

Manufacturer Part Number
DS21Q43AT
Description
IC FRAMER E1 QUAD 5V IND 128TQFP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS21Q43AT

Controller Type
E1 Framer
Interface
Parallel/Serial
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
32mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
128-TQFP, 128-VQFP
Dc
0319
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS21Q43AT
Quantity:
6
Part Number:
DS21Q43AT
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS21Q43AT
Manufacturer:
DALLAS
Quantity:
1 000
Part Number:
DS21Q43AT
Manufacturer:
MAXIM/美信
Quantity:
20 000
Company:
Part Number:
DS21Q43AT
Quantity:
290
Part Number:
DS21Q43AT+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS21Q43AT+
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS21Q43ATN
Manufacturer:
DALLAS
Quantity:
20 000
RCR1: RECEIVE CONTROL REGISTER 1 (Address=10 Hex)
(MSB)
RSMF
SYMBOL
RESYNC
SYNCE
RSMF
RSIO
RSM
FRC
-
-
RSM
POSITION
RCR1.7
RCR1.6
RCR1.5
RCR1.4
RCR1.3
RCR1.2
RCR1.1
RCR1.0
RSIO
NAME AND DESCRIPTION
RSYNC Multiframe Function. Only used if the RSYNC pin is
programmed in the multiframe mode (RCR1.6=1).
0=RSYNC outputs CAS multiframe boundaries.
1=RSYNC outputs CRC4 multiframe boundaries.
RSYNC Mode Select.
0=frame mode (see the timing in Section 11).
1=multiframe mode (see the timing in Section 11).
RSYNC I/O Select.
0=RSYNC is an output (depends on RCR1.6).
1=RSYNC is an input (only valid if elastic store enabled).
(note: this bit must be set to 0 when RCR2.1=0).
Not Assigned. Should be set to 0 when written.
Not Assigned. Should be set to 0 when written.
Frame Resync Criteria.
0=resync if FAS received in error 3 consecutive times.
1=resync if FAS or bit 2 of non-FAS is received in error 3
consecutive times.
Sync Enable.
0=auto resync enabled.
1=auto resync disabled.
Resync. When toggled from low to high, a resync is initiated.
Must be cleared and set again for a subsequent resync.
-
15 of 60
-
FRC
SYNCE
RESYNC
DS21Q43A
(LSB)

Related parts for DS21Q43AT